A cavity wall is a type of wall that has an airspace between the outer face and the inner, usually structural, construction. The skins typically are masonry , such as brick or cinder block . Masonry is an absorbent material that can retain rainwater or condensation. One function of the cavity is to drain water through weep holes at the base of the wall system or above windows. The weep holes provide a drainage path through the cavity that allows accumulated water an outlet to the exterior of the structure. Usually, weep holes are created by leaving out mortar at the vertical joints between bricks at regular intervals, by the insertion of tubes, or by inserting an absorbent wicking material into the joint. Weep holes are placed wherever a cavity is interrupted by a horizontal element, such as door or window lintels, masonry bearing angles, or slabs. A cavity wall with masonry as both inner and outer vertical elements is more commonly referred to as a double wythe masonry wall .

#371628

75-469: CIGA may refer to: Cavity Insulation Guarantee Agency UK provider of guarantee and operator of certification scheme for cavity wall insulation Compagnia Italiana Grandi Alberghi , a defunct hotel company purchased by ITT Sheraton in 1994 Council of Irish Guiding Associations , national Guiding federation of the Republic of Ireland Topics referred to by

150-492: A radiant barrier ) but it can also involve a range of designs and techniques to address the main modes of heat transfer - conduction, radiation, and convection materials. Most of the materials in the above list only retain a large amount of air or other gases between the molecules of the material. The gas conducts heat much less than the solids. These materials can form gas cavities, which can be used to insulate heat with low heat transfer efficiency. This situation also occurs in

225-642: A combination of both types to make up a total building insulation system. The type of insulation used is matched to create maximum resistance to each of the three forms of building heat transfer - conduction, convection, and radiation. According to three ways of heat exchange, most thermal insulation we use in our buildings can be divided into two categories: Conductive and convective insulators and radiant heat barriers. And there are more detailed classifications to distinguish between different materials. Many thermal insulation materials work by creating tiny air cavities between molecules, these air cavities can largely reduce

300-521: A continuous path across a temperature difference, in which the heat flow is not interrupted by thermal insulation. Common building materials that are poor insulators include glass and metal . A building design may have limited capacity for insulation in some areas of the structure. A common construction design is based on stud walls, in which thermal bridges are common in wood or steel studs and joists , which are typically fastened with metal. Notable areas that most commonly lack sufficient insulation are

375-625: A higher insulation value (the legally obtained level), then this value counts as a lower limit. Insulation requirements for new houses and small buildings in New Zealand are set out in the Building Code and standard NZS 4128:2009. Zones 1 and 2 include most of the North Island , including Waiheke Island and Great Barrier Island . Zone 3 includes the Taupo District , Ruapehu District , and

450-629: A relatively high R-value of around R-10 per inch which is considerably higher compared with conventional plastic foam insulation materials, due to their designed high porosity. But the difficulties in processing and low productivity limit the development of Aerogels, the cost price of this material still remains at a high level. Only two companies in the United States offer the commercial Aerogel product for wall insulation purposes. The DOE estimates thermal losses nearing 30% through windows, and thermal gains from sunlight leading to unwanted heating. Due to

525-452: A researcher at the University of Colorado Boulder, recently demonstrated the capabilities of aerogels by designing a silanized cellulose aerogel (SiCellA) which offers near 99% visible transmission in addition to thermal conductivities which effectively reject or retain heat depending on the interior environment, akin to heating/cooling alterations. This is due to the designed 97.5% porosity of

600-419: A routine part of a whole-house energy audit . However, you can sometimes perform a self-assessment in certain areas of the home, such as attics. Here, a visual inspection, along with use of a ruler, can give you a sense of whether you may benefit from additional insulation. Residential energy audits are often initiated due homeowners being alerted by a gradual increase in their utility bills which often reflects

675-455: A significant role in buildings, great demands of thermal comfort result in a large amount of energy consumed for full-heating for all rooms. Around 40% of energy consumption can be attributed to the building, mainly consumed by heating or cooling. Sufficient thermal insulation is the fundamental task that ensures a healthy indoor environment and against structure damages. It is also a key factor in dealing with high energy consumption, it can reduce

750-412: A thinner thickness of thermal insulation to the building shell compared with traditional materials. The VIPs are usually composed of core panels and metallic enclosures. The common materials that used to produce Core panels are fumed and precipitated silica, open-cell polyurethane (PU), and different types of fiberglass. And the core panel is covered by the metallic enclosure to create a vacuum environment,

825-462: Is an important climate change mitigation tactic , especially when buildings are heated by oil, natural gas, or coal-based electricity. Local and national governments and utilities often have a mix of incentives and regulations to encourage insulation efforts on new and renovated buildings as part of efficiency programs in order to reduce grid energy use and its related environmental impacts and infrastructure costs. Thermal insulation usually refers to

SECTION 10

#1732847453372

900-446: Is composed of two masonry walls separated by an air space. The outer wall is made of brick and faces the outside of the building structure. The inner wall may be constructed of masonry units such as concrete block, structural clay, brick or reinforced concrete. These two walls are fastened together with metal ties or bonding blocks. The ties strengthen the cavity wall. The water barrier is a water-resistant membrane , either applied to

975-586: Is different from Wikidata All article disambiguation pages All disambiguation pages Cavity wall insulation Cavity walls were first used in Greco-Roman buildings, but fell out of use until the 19th century, when they were reintroduced in the United Kingdom, gaining widespread use in the 1920s. In the 20th century metal ties came into use to bind the layers together. Initially cavity widths were narrow and were primarily implemented to reduce

1050-509: Is lost or gained by transmission through the ceilings, walls, floors, windows, and doors. This heat reduction and acquisition are usually unwelcome. It not only increases the load on the HVAC system resulting in more energy wastes but also reduces the thermal comfort of people in the building. Thermal insulation in buildings is an important factor in achieving thermal comfort for its occupants. Insulation reduces unwanted heat loss or gain and can decrease

1125-556: Is material used in a building (specifically the building envelope ) to reduce the flow of thermal energy. While the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation , fire insulation , and impact insulation (e.g. for vibrations caused by industrial applications). Often an insulation material will be chosen for its ability to perform several of these functions at once. Since prehistoric times, humans have created thermal insulation with materials such as animal fur and plants. With

1200-408: Is the installation of an insulation board (e.g. foam board EPS XPS, wood fibre board, etc.) over the exterior outside wall. Another method is using insulated lumber framing for a thermal break inside the wall. Insulating buildings during construction is much easier than retrofitting, as generally the insulation is hidden, and parts of the building need to be deconstructed to reach them. Depending on

1275-466: Is the minimum insulation requirements based on climate, which is determined by the Building Code of Australia (BCA). The building in Australia applies insulation in roofs, ceilings, external walls, and various components of the building (such as Veranda roofs in the hot climate, Bulkhead, Floors). Bulkheads (wall section between ceilings which are in different heights) should have the same insulated level as

1350-591: Is weak and radiation dominates heat transfer across an air space. Radiant barriers must face an adequate air-gap to be effective. If refrigerative air-conditioning is employed in a hot, humid climate, then it is particularly important to seal the building envelope. Dehumidification of humid air infiltration can waste significant energy. On the other hand, some building designs are based on effective cross-ventilation instead of refrigerative air-conditioning to provide convective cooling from prevailing breezes. In hot dry climate regions like Egypt and Africa, thermal comfort in

1425-757: The Rangitikei District north of 39°50′ latitude south (i.e. north of and including Mangaweka ) in the North Island, the South Island , Stewart Island , and the Chatham Islands . Insulation requirements are specified in the Building regulations and in England and Wales the technical content is published as Approved Documents Document L defines thermal requirements, and while setting minimum standards can allow for

1500-401: The 1995 versions reduced energy depletion per square meter for heating by 20%, and the 2000 version reduced by 40%. The code also has a mandatory requirement on thermal insulation of buildings accompany with some voluntary provisions, mainly focused on heat loss from the building shell. The thermal insulation requirements of Australia follow the climate of the building location, the table below

1575-418: The 19th century, people were no longer satisfied with using natural materials for thermal insulation, they processed the organic materials and produced the first insulated panels. At the same time, more and more artificial materials start to emerge, and a large range of artificial thermal insulation materials were developed, e.g. rock wool, fiberglass, foam glass, and hollow bricks. Thermal insulation can play

SECTION 20

#1732847453372

1650-545: The CWIVA took the debate to the houses of parliament discussing the cavity wall insulation industry. Breathing performance; early cavity wall buildings exchange moisture readily with the indoor and outdoor environment. Materials used for repairs must be selected with care to not affect the materials' breathing performance. Cavity wall insulation installed in older buildings can create problems with moisture retention. Thermal mass cavity walls are thick walls. These help stabilize

1725-464: The Netherlands makes a clear distinction between home renovation or newly built houses. New builds count as completely new homes, but also new additions and extensions are considered to be new builds. Furthermore, renovations whereby at least 25% of the surface of the integral building is changed or enlarged is also considered to be a new build. Therefore, during thorough renovations, there's a chance that

1800-586: The SiCellA: pores are smaller than the wavelength of visible light, leading to transmission; the pores also minimize contact between the cellulose fibers, leading to lower thermal conductivities. The use of cellulose fibers lends itself to sustainability, as this is a naturally derived fiber sourced from wood pulps. This opens the door not only to aerogels, but also more general wood-based materials implementation in an effort to assist sustainable design alternatives with compounding energy saving effects. In hot conditions,

1875-488: The U values for elements such as roofs and walls to be traded off against other factors such as the type of heating system in a whole building energy use assessment. Scotland and Northern Ireland have similar systems but the detail technical standards are not identical. The standards have been revised several times in recent years, requiring more efficient use of energy as the UK moves towards a low-carbon economy . In cold conditions,

1950-556: The agricultural development, earth, stone, and cave shelters arose. In the 19th century, people started to produce insulated panels and other artificial materials. Now, insulation is divided into two main categories: bulk insulation and reflective insulation. Buildings typically use a combination. Insulation is an important economic and environmental investment for buildings. By installing insulation, buildings use less energy for heating and cooling and occupants experience less thermal variability. Retrofitting buildings with further insulation

2025-404: The amount of non-insulative (particularly non-solar facing) glazing. Indoor thermal radiation can also be a disadvantage with spectrally selective (low-e, low-emissivity ) glazing. Some insulated glazing systems can double to triple R values. The vacuum panels and aerogel wall surface insulation are two technologies that can enhance the energy performance and thermal insulating effectiveness of

2100-633: The building performance was introduced in 2002. And the 2009 version of the Energy Saving Ordinance increased the minimum R-values of the thermal insulation of the building shell and introduced requirements for air-tightness tests. The Energy Saving Ordinance (EnEV) 2013 clarified the requirement of thermal insulation of the ceiling. And it mentioned that if the ceiling was not fulfilled, thermal insulation will be needed in accessible ceilings over upper floor's heated rooms. [U-Value must be under 0.24 W/(m ⋅K)] The building decree (Bouwbesluit) of

2175-796: The buildings attic as being poorly insulated. An initial estimate of insulation needs in the United States can be determined by the US Department of Energy's ZIP code insulation calculator . In Russia , the availability of abundant and cheap gas has led to poorly insulated, overheated, and inefficient consumption of energy. The Russian Center for Energy Efficiency found that Russian buildings are either over- or under-heated, and often consume up to 50 percent more heat and hot water than needed. 53 percent of all carbon dioxide (CO 2 ) emissions in Russia are produced through heating and generating electricity for buildings. However, greenhouse gas emissions from

2250-493: The ceilings since they suffer the same temperature levels. And the external walls of Australia's building should be insulated to decrease all kinds of heat transfer. Besides the walls and ceilings, the Australia energy code also requires insulation for floors (not all floors). Raised timber floors must have around 400mm soil clearance below the lowest timbers to provide sufficient space for insulation, and concrete slab such as suspended slabs and slab-on-ground should be insulated in

2325-582: The climate zone, it means that the amount of insulation needed for a building is determined by which climate zone the building locates. The thermal insulation requirements are shown as R-value and continuous insulation R-value as the second index. The requirements for different types of walls (wood framed walls, steel framed walls, and mass walls) are shown in the table. To determine whether you should add insulation, you first need to find out how much insulation you already have in your home and where. A qualified home energy auditor will include an insulation check as

CIGA - Misplaced Pages Continue

2400-401: The cold climate areas, a large amount of thermal insulation is needed to deal with the heat losses caused by cold weather (infiltration, ventilation, and radiation). There are two technologies that are worth discussing: VIPs are noted for their ultra-high thermal resistance, their ability of thermal resistance is four to eight times more than conventional foam insulation materials which lead to

2475-431: The context of sustainable architecture for green certifications such as LEED . The insulation strategy of a building needs to be based on a careful consideration of the mode of energy transfer and the direction and intensity in which it moves. This may alter throughout the day and from season to season. It is important to choose an appropriate design, the correct combination of materials, and building techniques to suit

2550-410: The corners of buildings, and areas where insulation has been removed or displaced to make room for system infrastructure, such as electrical boxes (outlets and light switches), plumbing, fire alarm equipment, etc. Thermal bridges can also be created by uncoordinated construction, for example by closing off parts of external walls before they are fully insulated. The existence of inaccessible voids within

2625-406: The correct installation of insulative materials. The less natural airflow into a building, the more mechanical ventilation will be required to support human comfort. High humidity can be a significant issue associated with lack of airflow, causing condensation , rotting construction materials, and encouraging microbial growth such as mould and bacteria . Moisture can also drastically reduce

2700-445: The country there are different regulations as to which type of insulation is the best alternative for buildings, considering energy efficiency and environmental factors. Geographical location also affects the type of insulation needed as colder climates will need a bigger investment than warmer ones on installation costs. There are essentially two types of building insulation - bulk insulation and reflective insulation. Most buildings use

2775-403: The drawback of this technology is obvious that the high reflectivity will cause visual discomfort. On the other hand, the high reflectivity and thermal emittance of the roof will increase the heating load of the building. Optimal placement of building elements (e.g. windows, doors, heaters) can play a significant role in insulation by considering the impact of solar radiation on the building and

2850-422: The effectiveness of insulation by creating a thermal bridge (see below). Air exchange systems can be actively or passively incorporated to address these problems. Thermal bridges are points in the building envelope that allow heat conduction to occur. Since heat flows through the path of least resistance, thermal bridges can contribute to poor energy performance. A thermal bridge is created when materials create

2925-591: The energy demands of heating and cooling systems. It does not necessarily deal with issues of adequate ventilation and may or may not affect the level of sound insulation. In a narrow sense, insulation can just refer to the insulation materials employed to slow heat loss, such as: cellulose , glass wool , rock wool , polystyrene , polyurethane foam , vermiculite , perlite , wood fiber , plant fiber ( cannabis , flax , cotton , cork , etc.), recycled cotton denim , straw , animal fiber ( sheep's wool ), cement , and earth or soil, reflective insulation (also known as

3000-642: The former Soviet Bloc are still below their 1990 levels. Energy codes in the Soviet Union start to establish in 1955, norms and rules first mentioned the performance of the building envelope and heat losses, and they formed norms to regulate the energy characteristics of the building envelope. And the most recent version of Russia energy code (SP 50.13330.2012) was published in 2003. The energy codes of Russia were established by experts of government institutes or nongovernmental organization like ABOK. The energy code of Russia have been revised several times since 1955,

3075-511: The former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K ⋅m . For example, in the US the insulation standard for attics, is recommended to be at least R-38 US units, (equivalent to R-6.7 or a U value of 0.15 in SI units). The equivalent standard in the UK are technically comparable, the approved document L would normally require an average U value over

CIGA - Misplaced Pages Continue

3150-521: The fur of animals and birds feathers, animal hair can employ the low thermal conductivity of small pockets of gas, so as to achieve the purpose of reducing heat loss. The effectiveness of reflective insulation (radiant barrier) is commonly evaluated by the reflectivity (emittance) of the surface with airspace facing to the heat source. The effectiveness of bulk insulation is commonly evaluated by its R-value , of which there are two – metric (SI) (with unit K⋅W ⋅m ) and US customary (with unit °F⋅ft ⋅h/BTU),

3225-479: The greatest source of heat energy is solar radiation. This can enter buildings directly through windows or it can heat the building shell to a higher temperature than the ambient, increasing the heat transfer through the building envelope. The Solar Heat Gain Co-efficient (SHGC) (a measure of solar heat transmittance) of standard single glazing can be around 78–85%. Solar gain can be reduced by adequate shading from

3300-416: The heat exchange through the materials. But there are two exceptions which don't use air cavities as their functional element to prevent heat transfer. One is reflective thermal insulation, which creates a great airspace by forming a radiation barrier by attaching metal foil on one side or both sides, this thermal insulation mainly reduces the radiation heat transfer. Although the polished metal foil attached on

3375-460: The heat exchange. Later, human beings' long life spans and the development of agriculture determined that they needed a fixed place of residence, earth-sheltered houses , stone houses, and cave dwellings began to emerge. The high density of these materials can cause a time lag effect in thermal transfer, which can make the inside temperature change slowly. This effect keep inside of the buildings warm in winter and cool in summer, also because of

3450-427: The heat flow through the building envelope. Good thermal insulation can also bring the following benefits to the building: How much insulation a house should have depends on building design, climate, energy costs, budget, and personal preference. Regional climates make for different requirements. Building codes often set minimum standards for fire safety and energy efficiency , which can be voluntarily exceeded within

3525-436: The high R associated with aerogels, their use for glazing applications has become an area of interest explored by many research institutions. Their implementation, however, must not hinder the primary function of windows: transparency. Typically, aerogels have low transmission and appear hazy, even amongst those considered transparent, which is why they have generally been reserved to wall insulation applications. Eldho Abraham,

3600-423: The inner side of the cavity as a film or as a troweled or sprayed liquid. The flashing component is important. Its main purpose is to direct water out of the cavity. Metal flashing usually extends from the interior wall through the outer wall and a weep hole with a downward curve allows the water to drain. Flashing systems in cavity walls are typically located close to the base of the wall, so that it will collect

3675-430: The installation of insulation, the definition of local rain exposure zones, and the creation of British Standard BS 8104 in 1992 that sets out the calculation procedure for assessing exposure of walls to wind driven rain to guide the installation of insulation. A significant number of properties that had the insulation installed by successive UK government-backed schemes were installed incorrectly or were unsuitable for

3750-454: The interior environment of a building better than thinner modern walls. Environmental Influences: The orientation or design of a building may affect the performance of different façades on a building. Some walls may receive more rainwater and wind than others depending in their orientation or protection to some of the faces. Moisture is one of the main problems in materials weathering. Building insulation Building insulation

3825-638: The main aim is to reduce heat flow out of the building. The components of the building envelope—windows, doors, roofs, floors/foundations, walls, and air infiltration barriers—are all important sources of heat loss; in an otherwise well insulated home, windows will then become an important source of heat transfer. The resistance to conducted heat loss for standard single glazing corresponds to an R-value of about 0.17 m ⋅K⋅W or more than twice that for typical double glazing (compared to 2–4 m ⋅K⋅W for glass wool batts ). Losses can be reduced by good weatherisation , bulk insulation, and minimising

SECTION 50

#1732847453372

3900-401: The material, since the edge of the vacuum panel can form a thermal bridge which leads to a reduction of the effectiveness of the vacuum insulation. The effectiveness of the vacuum insulation is also related to the area of the vacuum panels. Bulk insulators block conductive heat transfer and convective flow either into or out of a building. Air is a very poor conductor of heat and therefore makes

3975-402: The materials can only prevent the radiation heat transfer, its effect to stop heat transfer can be dramatic. Another thermal insulation that doesn't apply air cavities is vacuum insulation, the vacuum-insulated panels can stop all kinds of convection and conduction and it can also largely mitigate the radiation heat transfer. But the effectiveness of vacuum insulation is also limited by the edge of

4050-524: The materials like earth or stone is easy to get, this design is really popular in many places like Russia, Iceland, Greenland. Organic materials were the first available to build a shelter for people to protect themselves from bad weather conditions and to help keep them warm. But organic materials like animal and plant fiber cannot exist for a long time, so these natural materials cannot satisfy people's long-term need for thermal insulation. So, people began to search for substitutes which are more durable. In

4125-432: The materials of animal skins , fur , and plant materials like reed , flax , and straw , these materials were first used as clothing materials, because their dwellings were temporary, they were more likely to use the materials they used in clothing, which were easy to obtain and process. The materials of animal furs and plant products can hold a large amount of air between molecules which can create an air cavity to reduce

4200-423: The metallic enclosure can make sure that the core panel is kept in the vacuum environment. Although this material has a high thermal performance, it still maintains a high price in the last twenty years. Aerogel was first discovered by Samuel Stephens Kistle in 1931. It is a kind of gel of which the liquid component of the material is replaced by a gas, thus creating a material that is 99% air. This material has

4275-424: The new construction must meet the new building requirement for insulation of the Netherlands. If the renovation is of a smaller nature, the renovation directive applies. Examples of renovation are post-insulation of a cavity wall and post-insulation of a sloping roof against the roof boarding or under the tiles. Note that every renovation must meet the minimum Rc value of 1.3 W/(m ⋅K). If the current insulation has

4350-537: The particular situation. The thermal insulation requirements in the USA follow the ASHRAE 90.1 which is the U.S. energy standard for all commercial and some residential buildings. ASHRAE 90.1 standard considers multiple perspectives such as prescriptive, building envelope types and energy cost budget. And the standard has some mandatory thermal insulation requirements. All thermal insulation requirements in ASHRAE 90.1 are divided by

4425-404: The passage of moisture into the interior of the building. The introduction of insulation into the cavity became standard in the 1970s and then required by most building codes in the 1990s. A tie in a cavity wall is used to secure the internal and external walls, typically using metal tie straps or truss-like assemblies of welded wire that link the masonry thicknesses together. A cavity wall

4500-506: The past, architects used thermal mass materials to improve thermal comfort, the heavy thermal insulation could cause the time-lag effect which might slow down the speed of heat transfer during the daytime and keep the indoor temperature in a certain range (Hot and dry climate regions usually have a large temperature difference between the day and night). The cool roof is low-cost technology based on solar reflectance and thermal emittance, which uses reflective materials and light colors to reflect

4575-551: The prevailing breezes. Reflective laminates can help reduce passive solar heat in pole barns, garages, and metal buildings. See insulated glass and quadruple glazing for discussion of windows. The thermal envelope defines the conditioned or living space in a house. The attic or basement may or may not be included in this area. Reducing airflow from inside to outside can help to reduce convective heat transfer significantly. Ensuring low convective heat transfer also requires attention to building construction ( weatherization ) and

SECTION 60

#1732847453372

4650-615: The properties and density of the insulation material itself are critical. Most countries have some regime of either inspections or certification of approved installers to make sure that good standards are maintained. The history of thermal insulation is not so long compared with other materials, but human beings have been aware of the importance of insulation for a long time. In the prehistoric time, human beings began their activity of making shelters against wild animals and heavy weather, human beings started their exploration of thermal insulation. Prehistoric peoples built their dwellings by using

4725-530: The property. Incorrectly installed cavity wall insulation (CWI) causes water to seep into a property's walls, causing structural problems and damp patches that may also manifest into mould. In some cases, the damp and mould resulting from CWI can cause health problems or exacerbate existing conditions, particularly respiratory conditions. This has led to the formation of the Cavity Wall Insulation Victims Alliance (CWIVA). On 3 February 2015

4800-483: The residential buildings and commercial buildings in cold climate regions such as New England and Boston. In the past time, the price of thermal insulation materials that displayed high insulated performance was very expensive. With the development of material industry and the booming of science technologies, more and more insulation materials and insulated technologies have emerged during the 20th century, which gives us various options for building insulation. Especially in

4875-482: The roof area of 0.11 to 0.18 depending on the age of the property and the type of roof construction. Newer buildings have to meet a higher standard than those built under previous versions of the regulations. It is important to realise a single R-value or U-value does not take into account the quality of construction or local environmental factors for each building. Construction quality issues can include inadequate vapor barriers and problems with draft-proofing. In addition,

4950-404: The same term [REDACTED] This disambiguation page lists articles associated with the title CIGA . If an internal link led you here, you may wish to change the link to point directly to the intended article. Retrieved from " https://en.wikipedia.org/w/index.php?title=CIGA&oldid=986327192 " Category : Disambiguation pages Hidden categories: Short description

5025-518: The same way. China has various climatic characters, which are divided by geographical areas. There are five climate zones in China to identify the building design include thermal insulation. (The very cold zone, cold zone, hot summer and cold winter zone, hot summer and warm winter zone and cold winter zone). Germany established its requirements of building energy efficiency in 1977, and the first energy code-the Energy Saving Ordinance (EnEV) which based on

5100-421: The solar radiation. The solar reflectance and the thermal emittance are two key factors that determine the thermal performance of the roof, and they can also improve the effectiveness of the thermal insulation since around 30% solar radiation is reflected back to the sky. The shape of the roof is also under consideration, the curved roof can receive less solar energy compared with conventional shapes. Meanwhile,

5175-403: The summer is the main question, nearly half of energy consumption in urban area is depleted by air conditioning systems to satisfy peoples' demand for thermal comfort, many developing countries in hot dry climate region suffer a shortage of electricity in the summer due to the increasing use of cooling machines. A new technology called Cool Roof has been introduced to ameliorate this situation. In

5250-408: The sun, light coloured roofing , spectrally selective (heat-reflective) paints and coatings and, various types of insulation for the rest of the envelope. Specially coated glazing can reduce SHGC to around 10%. Radiant barriers are highly effective for attic spaces in hot climates. In this application, they are much more effective in hot climates than cold climates. For downward heat flow, convection

5325-572: The two wythes and, vertically, through the slabs, which minimizes thermal bridges . However, industry recommendations, often mandated by building codes, typically require that a cavity wall maintain at least a 1-inch (2.5 cm) drainage space free of masonry elements or insulation. Cavity wall insulation is used to reduce heat loss through a cavity wall by filling a portion of the air space with material that inhibits heat transfer. During construction of new buildings, cavities are often partially filled with rigid insulation panels placed between

5400-473: The two components of the wall In the United Kingdom , grants from the government and from energy companies are widely available to help with the cost of cavity wall insulation. The Affordable Warmth Objective (HHCRO) provides help for low income and vulnerable households to improve the energy efficiency of their properties and reduce heating bills. Government led research led to the development of advice on

5475-405: The use of appropriate insulation materials and design adaptations for buildings to slow the transfer of heat through the enclosure to reduce heat loss and gain. The transfer of heat is caused by the temperature difference between indoors and outdoors. Heat may be transferred either by conduction, convection, or radiation. The rate of transmission is closely related to the propagating medium. Heat

5550-446: The wall cavity which are devoid of insulation can be a source of thermal bridging. Some forms of insulation transfer heat more readily when wet, and can therefore also form a thermal bridge in this state. The heat conduction can be minimized by any of the following: reducing the cross sectional area of the bridges, increasing the bridge length, or decreasing the number of thermal bridges. One method of reducing thermal bridge effects

5625-399: The water that goes down the wall. Weep holes are drainage holes left in the exterior wall of the cavity wall, to provide an exit way for water in the cavity. Expansion and control joints do not have to be aligned in cavity walls. In modern cavity wall construction, cavity insulation is typically added. This construction makes it possible to add a continuous insulation layer between