Police Headquarters was a 1932 crime radio drama . Bruce Eells Associates produced this series which was syndicated to West Coast NBC radio stations. Each program lasted for about 15 minutes: music was featured in the first part of the show, an announcer would do a commercial or two, then the 12 minute episode would follow. A total of thirty-nine episodes were produced.
60-417: The program centered on a citizen reporting a crime via telephone and police use of two-way radio to set up a dragnet to find criminals and solve cases. While the programs were based upon actual cases, they were presented in the program as successfully solved, regardless of the actual outcome. The police in the drama would investigate a murder, a bank robbery, etc. and apprehend the perpetrators. In some cases
120-570: A bill of materials . This type of specification is a collaborative effort between a specification writer and a quantity surveyor . This approach is unusual in North America, where each bidder performs a quantity survey on the basis of both drawings and specifications. In many countries on the European continent, content that might be described as "specifications" in the United States are covered under
180-412: A functional specification (also, functional spec or specs or functional specifications document (FSD) ) is the set of documentation that describes the behavior of a computer program or larger software system . The documentation typically describes various inputs that can be provided to the software system and how the system responds to those inputs. Web services specifications are often under
240-456: A specification or standard. They are designed as systems with all equipment matched to perform together. For example, a modern, local government two-way radio system in the US may be designed to provide 95% area coverage in an urban area. System designers use radio frequency models, terrain models, and signal propagation modeling software in an attempt to accurately estimate where radios will work within
300-674: A "Structured Product Label" which drug manufacturers must by mandate use to submit electronically the information on a drug label. Recently, the ISO has made some progress in the area of food and drug standards and formal specifications for data about regulated substances through the publication of ISO 11238. In many contexts, particularly software, specifications are needed to avoid errors due to lack of compatibility, for instance, in interoperability issues. For instance, when two applications share Unicode data, but use different normal forms or use them incorrectly, in an incompatible way or without sharing
360-442: A defined geographic area. The models help designers choose equipment, equipment locations, antennas , and estimate how well signals will penetrate buildings. These models will be backed-up by drive testing and actual field signal level measurements. Designers adjust antenna patterns, add or move equipment sites, and design antenna networks in a way that will accomplish the intended level of performance. Many mobile and handhelds have
420-476: A fifteen-year life. Mobile radios are expected to last ten years. Walkie talkies typically last eight. In a State of California document, the Department of General Services reports expected service life for a communications console used in the Department of Forestry and Fire Protection is 10 years. Typical two-way radios work on fixed radio frequency channels, though some can scan multiple channels in order to find
480-446: A function of frequency. There are other factors that affect the range of a two-way radio such as weather, exact frequency used, and obstructions. Specification A specification often refers to a set of documented requirements to be satisfied by a material, design, product, or service. A specification is often a type of technical standard . There are different types of technical or engineering specifications (specs), and
540-411: A government or business contract. In engineering , manufacturing , and business , it is vital for suppliers , purchasers , and users of materials, products, or services to understand and agree upon all requirements. A specification may refer to a standard which is often referenced by a contract or procurement document, or an otherwise agreed upon set of requirements (though still often used in
600-478: A group to take turns talking. The radio is normally in receive mode so the user can hear all other transmissions on the channel. When the user wants to talk, they press a " push-to-talk " button, which turns off the receiver and turns on the transmitter; when the button is released, the receiver is activated again. Multiple channels are provided so separate user groups can communicate in the same area without interfering with each other and some radios are designed to scan
660-911: A limited duty cycle. Duty Cycle is the ratio of listening time to transmit time and is generally dependent on how well the transmitter can shed the heat from the heat sink on the rear of the radio. A 10% duty cycle (common on handhelds) translates to 10 seconds of transmit time to 90 seconds of receive time. Some mobile and base equipment is specified at different power levels – for example 100% duty cycle at 25 watts and 15% at 40 watts. In government systems, equipment may be replaced based on budgeting rather than any plan or expected service life. Funding in government agencies may be cyclical or sporadic. Managers may replace computing systems, vehicles, or budget computer and vehicle support costs while ignoring two-way radio equipment. Equipment may remain in use even though maintenance costs are unreasonable when viewed from an efficiency standpoint. One document says "seven years"
SECTION 10
#1732845118820720-402: A major investment has been made in actually implementing the design. An alternative approach is to use provably correct refinement steps to transform a specification into a design, and ultimately into an actual implementation, that is correct by construction. In (hardware, software, or enterprise) systems development, an architectural specification is the set of documentation that describes
780-639: A minimum set of interoperability specification, errors and data loss can result. For example, Mac OS X has many components that prefer or require only decomposed characters (thus decomposed-only Unicode encoded with UTF-8 is also known as "UTF8-MAC"). In one specific instance, the combination of OS X errors handling composed characters, and the samba file- and printer-sharing software (which replaces decomposed letters with composed ones when copying file names), has led to confusing and data-destroying interoperability problems. Applications may avoid such errors by preserving input code points, and normalizing them to only
840-435: A move to "greater use of performance and commercial specifications and standards" was to be introduced, which Perry saw as "one of the most important actions that [the Department of Defense] should take" at that time. The following British standards apply to specifications: A design/product specification does not necessarily prove a product to be correct or useful in every context. An item might be verified to comply with
900-437: A national government (including its different public entities, regulatory agencies , and national laboratories and institutes), a professional association (society), a purpose-made standards organization such as ISO , or vendor-neutral developed generic requirements. It is common for one organization to refer to ( reference , call out , cite ) the standards of another. Voluntary standards may become mandatory if adopted by
960-432: A separate range of tone pitches, for example. Digital systems may communicate text messages from computer-aided dispatch (CAD). For example, a display in a tow truck may give a textual location for a call and any related details. The tow truck driver may press an acknowledge button, sending data in the opposite direction and flagging the call as received by the driver. They can be used for analog telemetry systems, such as
1020-551: A specific list of products, or "open" allowing for substitutions made by the constructor. Most construction specifications are a combination of performance-based and proprietary types, naming acceptable manufacturers and products while also specifying certain standards and design criteria that must be met. While North American specifications are usually restricted to broad descriptions of the work, European ones and Civil work can include actual work quantities, including such things as area of drywall to be built in square meters, like
1080-494: A specific material type (concrete) or a work product (steel door) of the construction work. A specific material may be covered in several locations, depending on the work result: stainless steel (for example) can be covered as a sheet material used in flashing and sheet Metal in division 07; it can be part of a finished product, such as a handrail, covered in division 05; or it can be a component of building hardware, covered in division 08. The original listing of specification divisions
1140-402: A specification or stamped with a specification number: this does not, by itself, indicate that the item is fit for other, non-validated uses. The people who use the item ( engineers , trade unions , etc.) or specify the item ( building codes , government, industry, etc.) have the responsibility to consider the choice of available specifications, specify the correct one, enforce compliance, and use
1200-418: A valid transmission. In an analog, conventional system, (the simplest type of system) a frequency or channel serves as a physical medium or link carrying communicated information. The performance of a radio system is partly dependent on the characteristics of frequency band used. The selection of a frequency for a two-way radio system is affected, in part, by: The most common two-way radio systems operate in
1260-460: Is a mathematical description of software or hardware that may be used to develop an implementation . It describes what the system should do, not (necessarily) how the system should do it. Given such a specification, it is possible to use formal verification techniques to demonstrate that a candidate system design is correct with respect to that specification. This has the advantage that incorrect candidate system designs can be revised before
SECTION 20
#17328451188201320-523: Is a common early part of engineering design and product development processes in many fields. A functional specification is a kind of requirement specification, and may show functional block diagrams. A design or product specification describes the features of the solutions for the Requirement Specification, referring to either a designed solution or final produced solution. It is often used to guide fabrication/production. Sometimes
1380-553: Is a process for dealing with observations that are out-of-specification. The United States Food and Drug Administration has published a non-binding recommendation that addresses just this point. At the present time, much of the information and regulations concerning food and food products remain in a form which makes it difficult to apply automated information processing, storage and transmission methods and techniques. Data systems that can process, store and transfer information about food and food products need formal specifications for
1440-408: Is applied to wired communication systems where the circuit can send information in one direction at a time but not both directions at the same time. Analog systems may communicate a single condition, such as water level in a livestock tank. A transmitter at the tank site continually sends a signal with a constant audio tone. The tone would change in pitch to indicate the tank's water level. A meter at
1500-408: Is beyond the expected lifetime of walkie-talkies in police service. Batteries are cited as needing replacement more often. Twelve-year-old dispatch consoles mentioned in the same document were identified as usable. These were compared to problematic 21-year-old consoles used elsewhere in the same system. Another source says system backbone equipment like consoles and base stations are expected to have
1560-560: Is currently less fruitful and not yet put forward as an urgent agenda due to the tight restrictions of regional or national constitution. Specifications and other standards can be externally imposed as discussed above, but also internal manufacturing and quality specifications. These exist not only for the food or pharmaceutical product but also for the processing machinery , quality processes, packaging , logistics ( cold chain ), etc. and are exemplified by ISO 14134 and ISO 15609. The converse of explicit statement of specifications
1620-414: Is not covered by the above standards , it can be evaluated by the additional source of pharmacopoeias from other nations, from industrial specifications, or from a standardized formulary such as A similar approach is adopted by the food manufacturing, of which Codex Alimentarius ranks the highest standards, followed by regional and national standards. The coverage of food and drug standards by ISO
1680-528: Is owned by the Royal Institute of British Architects (RIBA) through their commercial group RIBA Enterprises (RIBAe). NBS master specifications provide content that is broad and comprehensive, and delivered using software functionality that enables specifiers to customize the content to suit the needs of the project and to keep up to date. UK project specification types fall into two main categories prescriptive and performance. Prescriptive specifications define
1740-554: Is used for bidirectional person-to-person voice communication with other users with similar radios, in contrast to a broadcast receiver, which only receives transmissions. Two-way radios usually use a half-duplex communication channel, which permits two-way communication, albeit with the limitation that only one user can transmit at a time. (This is in contrast to simplex communication , in which transmission can only be sent in one direction, and full-duplex, which allows transmission in both directions simultaneously.) This requires users in
1800-513: The VHF and UHF parts of the radio spectrum . Because this part of the spectrum is heavily used for broadcasting and multiple competing uses, spectrum management has become an important activity of governments to regulate radio users in the interests of both efficient and non-interfering use of radio. Both bands are widely applied for different users. The useful direct range of a two-way radio system depends on radio propagation conditions, which are
1860-513: The federal government and its agencies stipulates that a copy of the drawings and specifications must be kept available on a construction site. Specifications in Egypt form part of contract documents. The Housing and Building National Research Center ( HBRC ) is responsible for developing construction specifications and codes. The HBRC has published more than 15 books which cover building activities like earthworks , plastering, etc. Specifications in
Police Headquarters - Misplaced Pages Continue
1920-720: The structure , behavior , and more views of that system . A program specification is the definition of what a computer program is expected to do. It can be informal , in which case it can be considered as a user manual from a developer point of view, or formal , in which case it has a definite meaning defined in mathematical or programmatic terms. In practice, many successful specifications are written to understand and fine-tune applications that were already well-developed, although safety-critical software systems are often carefully specified prior to application development. Specifications are most important for external interfaces that must remain stable. In software development ,
1980-416: The 50 division format, which was adopted in both the United States and Canada starting in 2004. The 16 division format is no longer considered standard, and is not supported by either CSI or CSC, or any of the subscription master specification services, data repositories, product lead systems, and the bulk of governmental agencies. The United States' Federal Acquisition Regulation governing procurement for
2040-657: The Construction Specifications Institute and the Registered Specification Writer (RSW) through Construction Specifications Canada. Specification writers may be separate entities such as sub-contractors or they may be employees of architects, engineers, or construction management companies. Specification writers frequently meet with manufacturers of building materials who seek to have their products specified on upcoming construction projects so that contractors can include their products in
2100-641: The Galvin Manufacturing Corporation in 1940 for use by the police and military during World War II , and followed by the company's 1943 introduction of the Walkie-Talkie, the best-known example of a two-way radio. The first truly mobile two-way radio equipment was developed in Australia in 1923 by Senior Constable Frederick William Downie of the Victorian Police. The Victoria Police were
2160-588: The UK are part of the contract documents that accompany and govern the construction of a building. They are prepared by construction professionals such as architects , architectural technologists , structural engineers , landscape architects and building services engineers . They are created from previous project specifications, in-house documents or master specifications such as the National Building Specification (NBS). The National Building Specification
2220-523: The United States and are usually subscription based. Specifications can be either "performance-based", whereby the specifier restricts the text to stating the performance that must be achieved by the completed work, "prescriptive" where the specifier states the specific criteria such as fabrication standards applicable to the item, or "proprietary", whereby the specifier indicates specific products, vendors and even contractors that are acceptable for each workscope. In addition, specifications can be "closed" with
2280-517: The United States and updated every two years. While there is a tendency to believe that "specifications overrule drawings" in the event of discrepancies between the text document and the drawings, the actual intent must be made explicit in the contract between the Owner and the Contractor. The standard AIA (American Institute of Architects) and EJCDC (Engineering Joint Contract Documents Committee) states that
2340-478: The application's preferred normal form for internal use. Such errors may also be avoided with algorithms normalizing both strings before any binary comparison. However errors due to file name encoding incompatibilities have always existed, due to a lack of minimum set of common specification between software hoped to be inter-operable between various file system drivers, operating systems, network protocols, and thousands of software packages. A formal specification
2400-524: The building code or municipal code. Civil and infrastructure work in the United States often includes a quantity breakdown of the work to be performed as well. Although specifications are usually issued by the architect 's office, specification writing itself is undertaken by the architect and the various engineers or by specialist specification writers. Specification writing is often a distinct professional trade, with professional certifications such as "Certified Construction Specifier" (CCS) available through
2460-425: The channels in order to find a valid transmission. Other two-way radio systems operate in full-duplex mode, in which both parties can talk simultaneously. This requires either two separate radio channels or channel sharing methods such as time-division duplex (TDD) to carry the two directions of the conversation simultaneously on a single radio frequency. The first two-way radio was an AM-only device introduced by
Police Headquarters - Misplaced Pages Continue
2520-455: The conditions of a system or object after years of operation, including the effects of wear and maintenance (configuration changes). Specifications are a type of technical standard that may be developed by any of various kinds of organizations, in both the public and private sectors. Example organization types include a corporation , a consortium (a small group of corporations), a trade association (an industry-wide group of corporations),
2580-447: The drama was identifying the perpetrator, while more often it was in apprehending them. This article about a radio show or program in the United States is a stub . You can help Misplaced Pages by expanding it . This article about mystery fiction is a stub . You can help Misplaced Pages by expanding it . Two-way radio A two-way radio is a radio transceiver (a radio that can both transmit and receive radio waves ), which
2640-651: The drawings and specifications are complementary, together providing the information required for a complete facility. Many public agencies, such as the Naval Facilities Command (NAVFAC) state that the specifications overrule the drawings. This is based on the idea that words are easier for a jury (or mediator) to interpret than drawings in case of a dispute. The standard listing of construction specifications falls into 50 Divisions , or broad categories of work types and work results involved in construction. The divisions are subdivided into sections, each one addressing
2700-463: The estimates leading to their proposals. In February 2015, ArCHspec went live, from ArCH (Architects Creating Homes), a nationwide American professional society of architects whose purpose is to improve residential architecture. ArCHspec was created specifically for use by licensed architects while designing SFR (Single Family Residential) architectural projects. Unlike the more commercial CSI/CSC (50+ division commercial specifications), ArCHspec utilizes
2760-1159: The first in the world to use wireless communication in cars, putting an end to the inefficient status reports via public telephone boxes which had been used until that time. The first sets occupied about half of the floor in the back seat of the Lancia patrol cars. In 1933, the Bayonne, New Jersey police department successfully operated a two-way system between a central fixed station and radio transceivers installed in police cars; this allowed rapidly directing police response in emergencies. Two-way radio systems can be classified in several ways depending on their attributes. In multi-channel systems, channels are used for separate purposes. Scan features are either not used or scan lists are intentionally kept short in emergency applications. Part of APCO Project 16 set standards for channel access times and delays caused by system overhead. Scan features can further increase these delays. One study said delays of longer than 0.4 seconds (400 milliseconds) in emergency services are not recommended. The term "half duplex"
2820-467: The item correctly. Validation of suitability is necessary. Public sector procurement rules in the European Union and United Kingdom require non-discriminatory technical specifications to be used to identify the purchasing organisation's requirements. The rules relating to public works contracts initially prohibited "technical specifications having a discriminatory effect" from 1971; this principle
2880-402: The livestock tank levels, as described above. Another possibility is the lubricating oil pressure in a transit bus engine, or the current speed of the bus. Analog conditions are translated into data words. Some systems send radio paging messages which can either 1) beep a paging receiver, 2) send a numeric message, or 3) send a text message. Engineered systems are designed to perform close to
2940-458: The more concise 16 traditional Divisions, plus a Division 0 (Scope & Bid Forms) and Division 17 (low voltage). Many architects, up to this point, did not provide specifications for residential designs, which is one of the reasons ArCHspec was created: to fill a void in the industry with more compact specifications for residential projects. Shorter form specifications documents suitable for residential use are also available through Arcom, and follow
3000-406: The organisation's current corporate objectives or priorities. Sometimes a guide or a standard operating procedure is available to help write and format a good specification. A specification might include: Specifications in North America form part of the contract documents that accompany and govern the drawings for construction of building and infrastructure projects. Specifications describe
3060-473: The quality and performance of building materials, using code citations and published standards, whereas the drawings or building information model (BIM) illustrates quantity and location of materials. The guiding master document of names and numbers is the latest edition of MasterFormat . This is a consensus document that is jointly sponsored by two professional organizations: Construction Specifications Canada and Construction Specifications Institute based in
SECTION 50
#17328451188203120-414: The rather voluminous commercial style of specifications too lengthy for most residential projects and therefore either produce more abbreviated specifications of their own or use ArCHspec (which was specifically created for residential projects). Master specification systems are available from multiple vendors such as Arcom, Visispec, BSD, and Spectext. These systems were created to standardize language across
3180-477: The remote end would vary, corresponding to the tone pitch, to indicate the amount of water present in the livestock tank. Similar methods can be used to telemeter any analog condition. This type of radio system serves a purpose equivalent to a four-to-twenty milliampere loop . In the US, mid-band 72–76 MHz or UHF 450–470 MHz interstitial channels are often used for these systems. Some systems multiplex telemetry of several analog conditions by limiting each to
3240-495: The representations of data about food and food products in order to operate effectively and efficiently. Development of formal specifications for food and drug data with the necessary and sufficient clarity and precision for use specifically by digital computing systems have begun to emerge from some government agencies and standards organizations: the United States Food and Drug Administration has published specifications for
3300-476: The requirements using generic or proprietary descriptions of what is required, whereas performance specifications focus on the outcomes rather than the characteristics of the components. Specifications are an integral part of Building Information Modeling and cover the non-geometric requirements. Pharmaceutical products can usually be tested and qualified by various pharmacopoeias . Current existing pharmaceutical standards include: If any pharmaceutical product
3360-421: The singular). In any case, it provides the necessary details about the specific requirements. Standards for specifications may be provided by government agencies, standards organizations ( SAE , AWS , NIST , ASTM , ISO / IEC , CEN / CENELEC , DoD , etc.), trade associations , corporations , and others. A memorandum published by William J. Perry , U.S. Defense Secretary , on 29 June 1994 announced that
3420-423: The term specification is here used in connection with a data sheet (or spec sheet ), which may be confusing. A data sheet describes the technical characteristics of an item or product, often published by a manufacturer to help people choose or use the products. A data sheet is not a technical specification in the sense of informing how to produce. An " in-service " or " maintained as " specification , specifies
3480-419: The term is used differently in different technical contexts. They often refer to particular documents, and/or particular information within them. The word specification is broadly defined as "to state explicitly or in detail" or "to be specific". A requirement specification is a documented requirement , or set of documented requirements, to be satisfied by a given material, design, product, service, etc. It
3540-460: Was based on the time sequence of construction, working from exterior to interior, and this logic is still somewhat followed as new materials and systems make their way into the construction process. Each section is subdivided into three distinct parts: "general", "products" and "execution". The MasterFormat and SectionFormat systems can be successfully applied to residential, commercial, civil, and industrial construction. Although many architects find
3600-435: Was extended to public supply contracts by the then European Communities' Directive 77/62/EEC coordinating procedures for the award of public supply contracts, adopted in 1976. Some organisations provide guidance on specification-writing for their staff and partners. In addition to identifying the specific attributes required of the goods or services being purchased, specifications in the public sector may also make reference to
#819180