The Hooper House , also known as Hooper House II , located in Bare Hills in Baltimore County, Maryland , was commissioned by philanthropist Edith Hooper , and designed by architects Marcel Breuer and Herbert Beckhard. Breuer had designed an addition to the Hoopers' prior home in Baltimore in 1948; that home is often referred to as "Hooper House I," which is why this newer residence is often called "Hooper House II." Ground was broken on the project in 1958 and the house was completed in 1959.
55-634: Hooper House may refer to: Hooper House (Baltimore County, Maryland) , historic house in the Bauhaus style by architect Marcel Breuer James E. Hooper House , Baltimore, Maryland, listed on the NRHP Hooper House (Swansea, Massachusetts) , historic house Bevard House , also known as Hooper House in Bradshaw, Maryland See also [ edit ] Hooper-Eliot House , Cambridge, Massachusetts, listed on
110-403: A "Window Energy Rating" WER, ranging from A for the best down through B and C etc. This takes into account a combination of the heat loss through the window (U value, the reciprocal of R-value ), the solar gain (g value), and loss through air leakage around the frame (L value). For example, an A Rated window will in a typical year gain as much heat from solar gain as it loses in other ways (however
165-403: A "spacer". A spacer, which may be of the warm edge type, is the piece that separates the two panes of glass in an insulating glass system, and seals the gas space between them. The first spacers were made primarily of steel and aluminum, which manufacturers thought provided more durability, and their lower price means that they remain common. However, metal spacers conduct heat (unless the metal
220-549: A glass seal, and the two panes were separated by less than the 0.5 inches (1.3 cm) typical of modern units. The brand name Thermopane has entered the vocabulary of the glazing industry as the genericized trademark for any IGU. Single pane glass is a very poor insulator (R-value of around 1, RSI below 0.2), so single panes provide very little insulation. Glass coatings are frequently employed such as partially reflective or colored coatings to reduce insolation, and coatings to reflect infrared. Low emissivity glass (low E glass)
275-519: A highly structural thermal barrier reduces condensation on the glass surface and improves insulation, as measured by the overall U-value . An older and established way to improve insulation performance is to replace air in the space with a lower thermal conductivity gas. Gas convective heat transfer is a function of viscosity and specific heat. Monatomic gases such as argon , krypton , and xenon are often used since (at normal temperatures) they do not carry heat in rotational modes , resulting in
330-409: A ladder with each window and trying to hold the window in place while securing retaining clips around the edges. However, current reproductions of these old-style storm windows can be made with detachable glass in the bottom pane that can be replaced with a detachable screen when desired. This eliminates the need for changing the entire storm window according to the seasons. Insulated glazing (IG) forms
385-601: A lower heat capacity than poly-atomic gases. Argon has a thermal conductivity 67% that of air, krypton has about half the conductivity of argon. Argon comprises nearly 1% of the atmosphere and is industrially isolated at moderate cost, whereas krypton and xenon are only trace elements which are expensive to extract. All particular noble gases are non-toxic, clear, odorless, chemically inert, and readily available because of their widespread application in industry. Some manufacturers also offer sulfur hexafluoride as an insulating gas, particularly as sound proofing . It has only 2/3
440-434: A made to order basis on factory production lines, but standard units are also available. The width and height dimensions, the thickness of the glass panes and the type of glass for each pane as well as the overall thickness of the unit must be supplied to the manufacturer. On the assembly line, spacers of specific thicknesses are cut and assembled into the required overall width and height dimensions and filled with desiccant. On
495-412: A parallel line, glass panes are cut to size and washed to be optically clear. An adhesive, primary sealant ( polyisobutylene ) is applied to the face of the spacer on each side and the panes pressed against the spacer. If the unit is gas-filled, two holes are drilled into the spacer of the assembled unit, lines are attached to draw out the air out of the space and replacing it (or leaving just vacuum) with
550-443: A reduced melting point is heated to join the components. This creates a glass seal that experiences increasing stress with increasing temperature differential across the unit. This stress may limit the maximum allowable temperature differential. One manufacturer provides a recommendation of 35 °C. Closely spaced pillars are required to reinforce the glazing to resist the pressure of the atmosphere. Pillar spacing and diameter limited
605-694: A single unit with a seal between the edges of the panes, was patented in the United States by Thomas Stetson in 1865. It was developed into a commercial product in the 1930s, when several patents were filed, and a product was announced by the Libbey-Owens-Ford Glass Company in 1944. Their product was sold under the Thermopane brand name, which had been registered as a trademark in 1941. The Thermopane technology differs significantly from contemporary IGUs. The two panes of glass were welded together by
SECTION 10
#1732844187496660-472: A space to reduce heat transfer across a part of the building envelope . A window with insulating glass is commonly known as double glazing or a double-paned window , triple glazing or a triple-paned window, or quadruple glazing or a quadruple-paned window, depending upon how many panes of glass are used in its construction. Insulating glass units (IGUs) are typically manufactured with glass in thicknesses from 3 to 10 mm (1/8" to 3/8"). Thicker glass
715-422: A structural, thermally improved aluminum thermal barrier air spacer in the insulating glass can improve acoustical performance by reducing the transmission of exterior noise sources in the fenestration system. Reviewing the glazing system components, including the air space material used in the insulating glass, can ensure overall sound transmission improvement. Transmittance is a measure of how much visible light
770-496: A very compact multi-layer sandwich of air and glass, which eliminates the need for storm windows. Screens may also be left installed year-round with insulated glazing, and they can be installed in a manner that permits installation and removal from inside the building, eliminating the requirement to climb up the exterior of the house to service the windows. It is possible to retrofit insulated glazing into traditional double-hung frames, though this would require significant modification to
825-414: Is a commercially available option for IGU construction. Low E glass is made by applying a Low E coating to a pane of glass. These are generally metallic coatings, usually applied onto the second or third glass surfaces of the unit, that have the effect of reflecting infrared light, and blocking or attenuating portions of the ultraviolet and visible light spectra. This can significantly reduce the solar gain of
880-429: Is available - with mid-pane insulation factors equivalent to walls. In some situations the insulation is in reference to noise mitigation . In these circumstances a large air space improves the noise insulation quality or sound transmission class . Asymmetric double glazing, using different thicknesses of glass rather than the conventional symmetrical systems (equal glass thicknesses used for both lights) will improve
935-402: Is eliminated, leaving radiation losses and conduction through the edge seal and required supporting pillars over the face area. These VIG units have most of the air removed from the space between the panes, leaving a nearly-complete vacuum . VIG units which are currently on the market are hermetically sealed along their perimeter with solder glass, that is, a glass frit (powdered glass) having
990-577: Is naturally dissipated and the R-value suffers. Since 2004, there are also some companies offering the same restoration process for failed double-glazed units in the UK, and there is one company offering restoration of failed IG units in Ireland since 2010. Temperature differences across the surface of glass panes can lead to cracks in the glass. This may occur where the glass is partially shaded and partially heated from
1045-458: Is often used as it gives far superior insulation, and sometimes others gases or even a vacuum are employed. Fitting a second pane of glass to improve insulation began in Scotland, Germany, and Switzerland in the 1870s. Insulating glass is an evolution from older technologies known as double-hung windows and storm windows . Traditional double-hung windows used a single pane of glass to separate
1100-509: Is passed by the glass expressed as a fraction. Some of the light will also be absorbed and reflected. Some types of light include radio waves. Notably, many low-e glass and semi-reflective metalised coatings greatly attenuate Wi-Fi and cell phone signals. The life of an IGU varies depending on the quality of materials used, size of gap between inner and outer pane, temperature differences, workmanship and location of installation both in terms of facing direction and geographic location, as well as
1155-732: Is so much glass. When this home was built, insulated glass was not as common as it is today - especially for windows as large as 8½ by 10 feet - and so all the glazing in the house is 1/4" plate glass, with an R-value of 1. Replacing it all with insulated glass to save energy would have a payback period several times the warranty for the new glazing - which has a perimeter seal between its two or more panes, subject to eventual failure. The original glass, which has no such failure mode, remains clear after 50 years. Marcel Breuer Digital Archives, http://breuer.syr.edu/project.php?id=566 Insulated glass Insulating glass ( IG ) consists of two or more glass window panes separated by
SECTION 20
#17328441874961210-489: Is thermally improved), undermining the ability of the insulated glass unit ( IGU ) to reduce heat flow. It may also result in water or ice forming at the bottom of the sealed unit because of the sharp temperature difference between the window and surrounding air. To reduce heat transfer through the spacer and increase overall thermal performance, manufacturers may make the spacer out of a less-conductive material such as structural foam. A spacer made of aluminum that also contains
1265-433: Is used in special applications. Laminated or tempered glass may also be used as part of the construction. Most units are produced with the same thickness of glass on both panes but special applications such as acoustic attenuation or security may require different thicknesses of glass to be incorporated in a unit. The space in between the panes provides the bulk of the insulation effect. It be filled with air, but argon
1320-405: Is usually more resistant to cracking. Given the thermal properties of the sash, frame, and sill, and the dimensions of the glazing and thermal properties of the glass, the heat transfer rate for a given window and set of conditions can be calculated. This can be calculated in kW (kilowatts), but more usefully for cost benefit calculations can be stated as kWh pa (kilowatt hours per annum), based on
1375-670: The IGU, which impacts both the thermal performance (R-value) and the Solar Heat Gain Coefficient (SHGC). Two types of low E coatings are available: hard coatings and soft coatings. Hard coatings are produced using tin oxide that is applied when the glass is still hot, and is absorbed into the glass, and are hard wearing and usually cheaper. Soft coatings are vacuum-sputtered onto the glass surface and have higher performance but are easily oxidized and damaged, and thus have to be protected by an inert gas fill. The glass panes are separated by
1430-869: The NRHP in Massachusetts Hooper–Lee–Nichols House , Cambridge, Massachusetts, listed on the NRHP in Massachusetts Robert "King" Hooper Mansion , Marblehead, Massachusetts, listed on the NRHP in Massachusetts Hooper–Bowler–Hillstrom House , Belle Plaine, Minnesota, listed on the NRHP in Minnesota Nash-Hooper House , Hillsborough, North Carolina, listed on the NRHP in North Carolina Dr. D. D. Hooper House , Sylva, North Carolina, listed on
1485-633: The National Register of Historic Places in Jackson County, North Carolina Jessie Jack Hooper House , Oshkosh, Wisconsin, listed on the National Register of Historic Places in Winnebago County, Wisconsin Topics referred to by the same term [REDACTED] This disambiguation page lists articles associated with the title Hooper House . If an internal link led you here, you may wish to change
1540-418: The acoustic attenuation properties of the IGU. If standard air spaces are used, sulfur hexafluoride can be used to replace or augment an inert gas and improve acoustical attenuation performance. Other glazing material variations affect acoustics. The most widely used glazing configurations for sound dampening include laminated glass with varied thickness of the interlayer and thickness of the glass. Including
1595-452: The conductivity of argon, but is stable, inexpensive, and dense. However, sulfur hexafluoride is an extremely potent greenhouse gas . In Europe, SF 6 falls under the F-Gas directive which controls and even bans its usage for various applications. Since 1 January 2006, SF 6 is banned as a tracer gas and in all applications except high-voltage switchgear . Practically speaking,
1650-422: The courtyard, broken only by a relatively narrow doorway to the front entry hall. In the two images below, the living area/bedrooms are to the right, and the living room/kitchen/dining room are on the left. The perspective is actually "backwards", in that these images are looking from the rear of the house towards the front door (facing west). Many images of the home are taken from this perspective, as this side of
1705-462: The desired gas. The lines are then removed and holes sealed to contain the gas. The more modern technique is to use an online gas filler, which eliminates the need to drill holes in the spacer. The purpose of primary sealant is to keep insulating gas from escaping and water vapor from entering. The units are then enveloped on the edge side using either polysulfide or silicone sealant or similar material as secondary sealant which restraints movements of
Hooper House - Misplaced Pages Continue
1760-421: The east. Not only is this impressive visually, but the "binuclear" design is extremely practical for the family occupying the home: guests can be entertained in the living room in the south wing of the house, without disturbing family members in their bedrooms in the north wing of the house. The impressive noise management is enhanced by the thick stone walls, one of which is on the side of the family wing facing
1815-429: The edge seals are installed by pushing an arrow-shaped indented one-way flexible lip into a slot on the extruded channel, and often cannot be easily extracted from the extruded slot to be replaced. In Canada, since the beginning of 1990, there are some companies offering servicing of failed IG units. They provide open ventilation to the atmosphere by drilling hole(s) in the glass and/or spacer. This solution often reverses
1870-608: The efficiency to about R-3. Using low emissivity glass on surface #2 will add another R-value. Properly designed triple-glazed IGUs with low emissivity coatings on surfaces #2 and #4 and filled with argon gas in the cavities. Certain multi-chambered IG units result in R-values as high as R-24. Vacuum Insulating Glass (VIG) units result in R-values as high as R-15 (center of glass). Combining a VIG unit with another glass pane and warm edge spacer result in R-18 (center of glass) or more depending upon
1925-449: The failures of commercial insulating glass units over a 25-year period. For a standard construction IG unit, condensation collects between the layers of glass when the perimeter seal has failed and when the desiccant has become saturated, and can generally only be eliminated by replacing the IGU. Seal failure and subsequent replacement results in a significant factor in the overall cost of owning IGUs. Large temperature differences between
1980-531: The fill gas if it were pure. Argon is commonly used in insulated glazing as it is the most affordable. Krypton, which is considerably more expensive, is not generally used except to produce very thin double glazing units or extremely high performance triple-glazed units. Xenon has found very little application in IGUs because of cost. Vacuum technology is also used in some non-transparent insulation products called vacuum insulated panels . IGUs are often manufactured on
2035-559: The framing system used to carry the unit. Some residential and most commercial glazing systems can accommodate the ideal thickness of a double-paned unit. Issues arise with the use of triple glazing to further reduce heat loss in an IGU. The combination of thickness and weight results in units that are too unwieldy for most residential or commercial glazing systems, particularly if these panes are contained in moving frames or sashes. This trade-off does not apply to vacuum insulated glass (VIG), or evacuated glazing, as heat loss due to convection
2090-462: The house faces the lake and is covered in glass, while the west wall is a long wall of Maryland fieldstone, broken only by the front door and otherwise relatively featureless. Every room except for the bathrooms, the "family room", and the kitchen are located along the home's periphery and therefore have an entire wall that is made of glass, half of which is a floor to ceiling sliding-glass door. The living room actually has three such doors because there
2145-590: The inner and outer panes stress the spacer adhesives, which can eventually fail. Units with a small gap between the panes are more prone to failure because of the increased stress. Atmospheric pressure changes combined with wet weather can, in rare cases, eventually lead to the gap filling with water. The flexible sealing surfaces preventing infiltration around the window unit can also degrade or be torn or damaged. Replacement of these seals can be difficult to impossible, due to IG windows commonly using extruded channel frames without seal retention screws or plates. Instead,
2200-661: The insulation achieved by designs available beginning in the 1990s to R = 4.7 h·°F·ft2/BTU (0.83 m2·K/W) no better than high quality double glazed insulated glass units. Recent products claim performance of R = 14 h·°F·ft2/BTU (2.5 m2·K/W) which exceeds triple glazed insulated glass units. The required internal pillars exclude applications where an unobstructed view through the glazing unit is desired, i.e. most residential and commercial windows, and refrigerated food display cases. VIG equipped windows, however, under-perform due to intense edge heat transfer. The insulation effectiveness can be expressed as an R-value or RSI value . The higher
2255-400: The insulation value up to a point, but eventually with a large enough gap, convection currents begin to flow carrying heat between the panes within the unit. Typically, most sealed units achieve maximum insulating values using a space of 16–19 mm (0.63–0.75 in) when measured at the centre of the IGU. IGU thickness is a compromise between maximizing insulating value and the ability of
Hooper House - Misplaced Pages Continue
2310-401: The interior and exterior spaces. Traditional storm windows and screens are relatively time-consuming and labor-intensive, requiring removal and storage of the storm windows in the spring and reinstallation in the fall and storage of the screens. The weight of the large storm window frame and glass makes replacement on upper-stories of tall buildings a difficult task requiring repeatedly climbing
2365-402: The link to point directly to the intended article. Retrieved from " https://en.wikipedia.org/w/index.php?title=Hooper_House&oldid=1221924107 " Category : Disambiguation pages Hidden categories: Short description is different from Wikidata All article disambiguation pages All disambiguation pages Hooper House (Baltimore County, Maryland) One of
2420-467: The low-e coating(s). Double VIG units with warm edge spacer reach R-25 (center of glass) or more depending upon low-e coatings and other factors. Additional layers of glazing provide the opportunity for improved insulation. While the standard double glazing is most widely used, triple glazing is not uncommon, and quadruple glazing is produced for cold environments such as Alaska or Scandinavia. Even quintuple and six-pane glazing (four or five cavities)
2475-434: The more effective a fill gas is at its optimum thickness, the thinner the optimum thickness is. For example, the optimum thickness for krypton is lower than for argon, and lower for argon than for air. However, since it is difficult to determine whether the gas in an IGU has become mixed with air at time of manufacture (or becomes mixed with air once installed), many designers prefer to use thicker gaps than would be optimum for
2530-429: The most immediately apparent as well as fundamentally important features of this home is its "binuclear" design: A central courtyard divides the house into living/dining/cooking/entertaining and family/bedroom areas. The front door faces the center of the courtyard, where glass doors and a large rectangular opening in the stone of the rear wall frame an unobstructed view literally through the home and to Lake Roland to
2585-432: The rubbery-plastic primary sealant. The desiccant will remove traces of humidity from the air space such that no condensation appears on the inside faces during cold weather. Some manufacturers have developed specific processes which combine the spacer and desiccant into a single step application system. The maximum insulating efficiency of a standard IGU is determined by the thickness of the space. Greater space increases
2640-606: The sunlight. Tinted glass increases heating and thermal stress, while annealing reduces internal stress built into the glass during manufacturing. Thermal expansion creates internal pressure, or stress, where expanding warm material is restrained by cooler material. Typically cracks initiate and propagate from the narrow shaded cut edge where the glass is cooler and minute grooves and notches cause stress concentration . Glass thickness has no direct effect on thermal cracking in windows because both thermal stress and material strength are proportional to thickness. Annealed and tempered glass
2695-451: The treatment the unit receives. IG units typically last from 10 to 25 years, with windows facing the equator often lasting less than 12 years. IGUs typically carry a warranty for 10 to 20 years depending upon the manufacturer. If IGUs are altered (such as installation of a window insulation film ) the warranty may be voided by the manufacturer. The Insulating Glass Manufacturers Alliance (IGMA) undertook an extensive study to characterize
2750-409: The typical conditions over a year for a given location. The glass panels in double-glazed windows transmit heat in both directions by radiation, through the glazing by conduction and across the gap between the panes by convection, by conduction through the frame, and by infiltration around the perimeter seals and the frame's seal to the building. The actual rates will vary with the conditions throughout
2805-432: The value, the greater is its resistance to heat transfer. A standard IGU consisting of clear uncoated panes of glass (or lights) with air in the cavity between the lights typically has an RSI-value of 0.35 K·m /W. Using US customary units , a rule of thumb in standard IGU construction is that each change in the component of the IGU results in an increase of 1 R-value to the efficiency of the unit. Adding argon gas increases
SECTION 50
#17328441874962860-450: The visible condensation, but cannot clean the interior surface of the glass and staining that may have occurred after long-term exposure to moisture. They may offer a warranty from 5 to 20 years. This solution lowers the insulating value of the window, but it can be a "green" solution when the window is still in good condition. If the IG unit had a gas fill (e.g. argon or krypton or a mixture) the gas
2915-408: The window and reducing air leakage. IG provides robust protection against the sun and keeps the house cool in the hot summer and warm in winter. The spring-operated balancing mechanisms also typically permit the top of the windows to swing inward, permitting cleaning of the exterior of the IG window from inside the building. The insulating glazing unit, consisting of two glass panes bound together into
2970-399: The wood frame due to the increased thickness of the IG assembly. Modern window units with IG typically completely replace the older double-hung unit and include other improvements such as better sealing between the upper and lower windows and spring-operated weight balancing that removes the need for large hanging weights inside the wall next to the windows, allowing for more insulation around
3025-521: The year, and while solar gain may be much welcomed in the winter (depending on local climate), it may result in increased air conditioning costs in the summer. Unwanted heat transfer can be mitigated by for example using curtains at night in the winter and using sun shades during the day in the summer. In an attempt to provide a useful comparison between alternative window constructions the British Fenestration Rating Council have defined
#495504