The Folin–Ciocâlteu reagent (FCR) or Folin's phenol reagent or Folin–Denis reagent , is a mixture of phosphomolybdate and phosphotungstate used for the colorimetric in vitro assay of phenolic and polyphenolic antioxidants , also called the gallic acid equivalence method (GAE). It is named after Otto Folin , Vintilă Ciocâlteu , and Willey Glover Denis . The Folin-Denis reagent is prepared by mixing sodium tungstate and phosphomolybdic acid in phosphoric acid . The Folin–Ciocalteu reagent is just a modification of the Folin-Denis reagent. The modification consisted of the addition of lithium sulfate and bromine to the phosphotungstic-phosphomolybdic reagent.
40-455: The reagent does not measure only phenols, but will react with any reducing substance. It therefore measures the total reducing capacity of a sample, not just phenolic compounds. This reagent is part of the Lowry protein assay , and will also react with some nitrogen-containing compounds such as hydroxylamine and guanidine . The reagent has also been shown to be reactive towards thiols, many vitamins,
80-406: A ) d . {\displaystyle -\ln(T)=\ln {\frac {I_{0}}{I_{s}}}=(\mu _{s}+\mu _{a})d\,.} If a size of a detector is very small compared to the distance traveled by the light, any light that is scattered by a particle, either in the forward or backward direction, will not strike the detector. (Bouguer was studying astronomical phenomena, so this condition was met.) In such case,
120-566: A ( z ) is uniform along the path, the attenuation is said to be a linear attenuation , and the relation becomes A = a l . {\displaystyle A=al.} Sometimes the relation is given using the molar attenuation coefficient of the material, that is its attenuation coefficient divided by its molar concentration : A = ∫ 0 l ε c ( z ) d z , {\displaystyle A=\int _{0}^{l}\varepsilon c(z)\,\mathrm {d} z\,,} where If c ( z )
160-449: A detector. Using this information, the wavelengths that were absorbed can be determined. First, measurements on a "blank" are taken using just the solvent for reference purposes. This is so that the absorbance of the solvent is known, and then any change in absorbance when measuring the whole solution is made by just the solute of interest. Then measurements of the solution are taken. The transmitted spectral radiant flux that makes it through
200-447: A homogeneous medium such as a solution, there is no scattering. For this case, researched extensively by August Beer , the concentration of the absorbing species follows the same linear contribution to absorbance as the path-length. Additionally, the contributions of individual absorbing species are additive. This is a very favorable situation, and made absorbance an absorption metric far preferable to absorption fraction (absorptance). This
240-644: A material is approximately equal to its attenuance when both the absorbance is much less than 1 and the emittance of that material (not to be confused with radiant exitance or emissivity ) is much less than the absorbance. Indeed, Φ e t + Φ e a t t = Φ e i + Φ e e , {\displaystyle \Phi _{\mathrm {e} }^{\mathrm {t} }+\Phi _{\mathrm {e} }^{\mathrm {att} }=\Phi _{\mathrm {e} }^{\mathrm {i} }+\Phi _{\mathrm {e} }^{\mathrm {e} }\,,} where This
280-597: A material. Absorbance is dimensionless , and in particular is not a length, though it is a monotonically increasing function of path length, and approaches zero as the path length approaches zero. The absorbance of a material, denoted A , is given by A = log 10 Φ e i Φ e t = − log 10 T , {\displaystyle A=\log _{10}{\frac {\Phi _{\text{e}}^{\text{i}}}{\Phi _{\text{e}}^{\text{t}}}}=-\log _{10}T,} where Absorbance
320-445: A plot of − ln ( T ) {\displaystyle -\ln(T)} as a function of wavelength will yield a superposition of the effects of absorption and scatter. Because the absorption portion is more distinct and tends to ride on a background of the scatter portion, it is often used to identify and quantify the absorbing species. Consequently, this is often referred to as absorption spectroscopy , and
360-417: A quantity of light incident on a sample or material to that which is detected after the light has interacted with the sample. The term absorption refers to the physical process of absorbing light, while absorbance does not always measure only absorption; it may measure attenuation (of transmitted radiant power) caused by absorption, as well as reflection, scattering, and other physical processes. Sometimes
400-435: A scattering sample is the same as the absorbance of the same thickness of the material in the absence of scatter. In optics , absorbance or decadic absorbance is the common logarithm of the ratio of incident to transmitted radiant power through a material, and spectral absorbance or spectral decadic absorbance is the common logarithm of the ratio of incident to transmitted spectral radiant power through
440-789: A uniform sample". For decadic absorbance, this may be symbolized as A 10 = − log 10 ( 1 − α ) {\displaystyle \mathrm {A} _{10}=-\log _{10}(1-\alpha )} . If a sample both transmits and remits light , and is not luminescent, the fraction of light absorbed ( α {\displaystyle \alpha } ), remitted ( R {\displaystyle R} ), and transmitted ( T {\displaystyle T} ) add to 1: α + R + T = 1 {\displaystyle \alpha +R+T=1} . Note that 1 − α = R + T {\displaystyle 1-\alpha =R+T} , and
SECTION 10
#1732856199354480-401: A uniform sample". The term is used in many technical areas to quantify the results of an experimental measurement. While the term has its origin in quantifying the absorption of light, it is often entangled with quantification of light which is "lost" to a detector system through other mechanisms. What these uses of the term tend to have in common is that they refer to a logarithm of the ratio of
520-611: Is a dimensionless quantity. Nevertheless, the absorbance unit or AU is commonly used in ultraviolet–visible spectroscopy and its high-performance liquid chromatography applications, often in derived units such as the milli-absorbance unit (mAU) or milli-absorbance unit-minutes (mAU×min), a unit of absorbance integrated over time. Absorbance is related to optical depth by A = τ ln 10 = τ log 10 e , {\displaystyle A={\frac {\tau }{\ln 10}}=\tau \log _{10}e\,,} where τ
560-504: Is an intense blue molecule known as heteropolymolybdenum Blue. The concentration of the reduced Folin reagent (heteropolymolybdenum Blue) is measured by absorbance at 660 nm. As a result, the total concentration of protein in the sample can be deduced from the concentration of tryptophan and tyrosine residues that reduce the Folin–Ciocalteu reagent. The method was first proposed by Lowry in 1951. The bicinchoninic acid assay and
600-406: Is being "extinguished". Bouguer recognized that this extinction (now often called attenuation) was not linear with distance traveled through the medium, but related by what we now refer to as an exponential function. If I 0 {\displaystyle I_{0}} is the intensity of the light at the beginning of the travel and I d {\displaystyle I_{d}}
640-518: Is called an attenuation constant (a term used in various fields where a signal is transmitted though a medium) or coefficient. The amount of light transmitted is falling off exponentially with distance. Taking the natural logarithm in the above equation, we get − ln ( T ) = ln I 0 I d = μ d . {\displaystyle -\ln(T)=\ln {\frac {I_{0}}{I_{d}}}=\mu d\,.} For scattering media,
680-537: Is equivalent to T + A T T = 1 + E , {\displaystyle T+\mathrm {ATT} =1+E\,,} where According to the Beer–Lambert law , T = 10 , so and finally Absorbance of a material is also related to its decadic attenuation coefficient by A = ∫ 0 l a ( z ) d z , {\displaystyle A=\int _{0}^{l}a(z)\,\mathrm {d} z\,,} where If
720-472: Is properly unitless, it is sometimes reported in "absorbance units", or AU. Many people, including scientific researchers, wrongly state the results from absorbance measurement experiments in terms of these made-up units. Absorbance is a number that measures the attenuation of the transmitted radiant power in a material. Attenuation can be caused by the physical process of "absorption", but also reflection, scattering, and other physical processes. Absorbance of
760-711: Is related to spectral optical depth by A ν = τ ν ln 10 = τ ν log 10 e , A λ = τ λ ln 10 = τ λ log 10 e , {\displaystyle {\begin{aligned}A_{\nu }&={\frac {\tau _{\nu }}{\ln 10}}=\tau _{\nu }\log _{10}e\,,\\A_{\lambda }&={\frac {\tau _{\lambda }}{\ln 10}}=\tau _{\lambda }\log _{10}e\,,\end{aligned}}} where Although absorbance
800-476: Is the molar attenuation coefficient or absorptivity of the attenuating species; ℓ {\displaystyle \ell } is the optical path length; and c {\displaystyle c} is the concentration of the attenuating species. For samples which scatter light, absorbance is defined as "the negative logarithm of one minus absorptance (absorption fraction: α {\displaystyle \alpha } ) as measured on
840-461: Is the case for which the term "absorbance" was first used. A common expression of the Beer's law relates the attenuation of light in a material as: A = ε ℓ c {\displaystyle \mathrm {A} =\varepsilon \ell c} , where A {\displaystyle \mathrm {A} } is the absorbance; ε {\displaystyle \varepsilon }
SECTION 20
#1732856199354880-465: Is the intensity of the light detected after travel of a distance d {\displaystyle d} , the fraction transmitted, T {\displaystyle T} , is given by T = I d I 0 = exp ( − μ d ) , {\displaystyle T={\frac {I_{d}}{I_{0}}}=\exp(-\mu d)\,,} where μ {\displaystyle \mu }
920-1133: Is the optical depth. Spectral absorbance in frequency and spectral absorbance in wavelength of a material, denoted A ν and A λ respectively, are given by A ν = log 10 Φ e , ν i Φ e , ν t = − log 10 T ν , A λ = log 10 Φ e , λ i Φ e , λ t = − log 10 T λ , {\displaystyle {\begin{aligned}A_{\nu }&=\log _{10}{\frac {\Phi _{{\text{e}},\nu }^{\text{i}}}{\Phi _{{\text{e}},\nu }^{\text{t}}}}=-\log _{10}T_{\nu }\,,\\A_{\lambda }&=\log _{10}{\frac {\Phi _{{\text{e}},\lambda }^{\text{i}}}{\Phi _{{\text{e}},\lambda }^{\text{t}}}}=-\log _{10}T_{\lambda }\,,\end{aligned}}} where Spectral absorbance
960-475: Is uniform along the path, the relation becomes A = ε c l . {\displaystyle A=\varepsilon cl\,.} The use of the term "molar absorptivity" for molar attenuation coefficient is discouraged. The amount of light transmitted through a material diminishes exponentially as it travels through the material, according to the Beer–Lambert law ( A = ( ε )( l ) ). Since
1000-460: The Hartree–Lowry assay are subsequent modifications of the original Lowry procedure. Absorbance Absorbance is defined as "the logarithm of the ratio of incident to transmitted radiant power through a sample (excluding the effects on cell walls)". Alternatively, for samples which scatter light, absorbance may be defined as "the negative logarithm of one minus absorptance, as measured on
1040-684: The 1945–1988 Science Citation Index , with 187,652 citations. Because it measures anti-oxidant capacity in vitro , the reagent has been used to assay foods and supplements in food science . The oxygen radical absorbance capacity (ORAC) used to be the industry standard for antioxidant strength of whole foods, juices and food additives. Earlier measurements and ratings by the United States Department of Agriculture were withdrawn in 2012 as biologically irrelevant to human health, referring to an absence of physiological evidence for polyphenols having antioxidant properties in vivo . Consequently,
1080-484: The Folin–Ciocalteu reaction). The reaction mechanism is not well understood, but involves reduction of the Folin–Ciocalteu reagent and oxidation of aromatic residues (mainly tryptophan , also tyrosine ). Proper caution must be taken when dealing with the Folin's reagent, which is only active in acidic conditions. Although this is true, the reduction reaction, as previously mentioned, will only occur in basic pH 10. Thus,
1120-446: The ORAC method, derived only from in vitro experiments, is no longer considered relevant to human diets or biology . The Trolox equivalent antioxidant capacity assay – also based on the presence of polyphenols – is an alternative in vitro measurements of antioxidant capacity. Lowry protein assay The Lowry protein assay is a biochemical assay for determining
1160-530: The absorbance of a sample is measured as a logarithm, it is directly proportional to the thickness of the sample and to the concentration of the absorbing material in the sample. Some other measures related to absorption, such as transmittance, are measured as a simple ratio so they vary exponentially with the thickness and concentration of the material. Any real measuring instrument has a limited range over which it can accurately measure absorbance. An instrument must be calibrated and checked against known standards if
1200-599: The constant is often divided into two parts, μ = μ s + μ a {\displaystyle \mu =\mu _{s}+\mu _{a}} , separating it into a scattering coefficient μ s {\displaystyle \mu _{s}} and an absorption coefficient μ a {\displaystyle \mu _{a}} , obtaining − ln ( T ) = ln I 0 I s = ( μ s + μ
1240-406: The formula for absorbance of a material discussed below. Even though this absorbance function is very useful with scattering samples, the function does not have the same desirable characteristics as it does for non-scattering samples. There is, however, a property called absorbing power which may be estimated for these samples. The absorbing power of a single unit thickness of material making up
Folin–Ciocalteu reagent - Misplaced Pages Continue
1280-409: The formula may be written as A 10 = − log 10 ( R + T ) {\displaystyle \mathrm {A} _{10}=-\log _{10}(R+T)} . For a sample which does not scatter, R = 0 {\displaystyle R=0} , and 1 − α = T {\displaystyle 1-\alpha =T} , yielding
1320-409: The nucleotide base guanine , the trioses glyceraldehyde and dihydroxyacetone , and some inorganic ions. Copper complexation increases the reactivity of phenols towards this reagent. This reagent is distinct from Folin's reagent , which is used to detect amines and sulfur-containing compounds. A 1951 paper entitled "Protein measurement with the Folin phenol reagent" was the most cited paper in
1360-423: The plotted quantity is called "absorbance", symbolized as A {\displaystyle \mathrm {A} } . Some disciplines by convention use decadic (base 10) absorbance rather than Napierian (natural) absorbance, resulting in: A 10 = μ 10 d {\displaystyle \mathrm {A} _{10}=\mu _{10}d} (with the subscript 10 usually not shown). Within
1400-558: The readings are to be trusted. Many instruments will become non-linear (fail to follow the Beer–Lambert law) starting at approximately 2 AU (~1% transmission). It is also difficult to accurately measure very small absorbance values (below 10 ) with commercially available instruments for chemical analysis. In such cases, laser-based absorption techniques can be used, since they have demonstrated detection limits that supersede those obtained by conventional non-laser-based instruments by many orders of magnitude (detection has been demonstrated all
1440-451: The reduction must occur before the reagent breaks down. Mixing the protein solution as the Folin's reagent is simultaneously added will ensure that the reaction occurs in the desired manner. Experiments have shown that cysteine is also reactive to the reagent. Therefore, cysteine residues in protein probably also contribute to the absorbance seen in the Lowry assay. The result of this reaction
1480-472: The scientific literature, cited over 300,000 times. The method combines the reactions of copper ions with the peptide bonds under alkaline conditions (the Biuret test ) with the oxidation of aromatic protein residues. The Lowry method is based on the reaction of Cu , produced by the oxidation of peptide bonds, with Folin–Ciocalteu reagent (a mixture of phosphotungstic acid and phosphomolybdic acid in
1520-433: The term "attenuance" or "experimental absorbance" is used to emphasize that radiation is lost from the beam by processes other than absorption, with the term "internal absorbance" used to emphasize that the necessary corrections have been made to eliminate the effects of phenomena other than absorption. The roots of the term absorbance are in the Beer–Lambert law . As light moves through a medium, it will become dimmer as it
1560-401: The total level of protein in a solution . The total protein concentration is exhibited by a color change of the sample solution in proportion to protein concentration, which can then be measured using colorimetric techniques . It is named for the biochemist Oliver H. Lowry who developed the reagent in the 1940s. His 1951 paper describing the technique is the most-highly cited paper ever in
1600-478: The way down to 5 × 10 ). The theoretical best accuracy for most commercially available non-laser-based instruments is attained in the range near 1 AU. The path length or concentration should then, when possible, be adjusted to achieve readings near this range. Typically, absorbance of a dissolved substance is measured using absorption spectroscopy . This involves shining a light through a solution and recording how much light and what wavelengths were transmitted onto