The Bang Lang Dam ( Thai : เขื่อนบางลาง , RTGS : Khuean Bang Lang , pronounced [kʰɯ̀a̯n bāːŋ lāːŋ] ), also known as the Pattani Dam ( เขื่อนปัตตานี , RTGS : Khuean Pattani , pronounced [kʰɯ̀a̯n pàt.tāː.nīː] ), is a multi-purpose hydroelectric dam in the Bannang Sata District of Yala Province , Thailand . It was the first multi-purpose dam developed in Thailand's southern region . The dam impounds the Pattani River , creating the Bang Lang Reservoir . The dam and its accompanying power plant were developed as part of the Pattani Project.
23-592: Bang Lang Dam is an earth core rockfill dam. It is 430 m (1,410 ft) long and 85 m (279 ft) high. Its reservoir has a maximum storage capacity of 1,420,000,000 m (5.0 × 10 cu ft) with a catchment area of 2,080 km (800 sq mi). The dam is considered multi-purpose supporting electricity generation, irrigation, flood control, fisheries and recreation activities. The dam's power plant has three hydroelectric Francis turbine -generating units, each with an installed capacity of 24 MW . A nearby mini hydroelectric project at Ban Santi has
46-521: A 1.275 MW generating unit and is also part of the Pattani Project. The combined annual power generation is 200 GWh . This article about a Thai building or structure is a stub . You can help Misplaced Pages by expanding it . This article about a dam or floodgate in Asia is a stub . You can help Misplaced Pages by expanding it . Francis turbine The Francis turbine is a type of water turbine . It
69-505: A new turbine design. Francis turbines are primarily used for producing electricity. The power output of the electric generators generally ranges from just a few kilowatts up to 1000 MW, though mini-hydro installations may be lower. The best performance is seen when the head height is between 100–300 metres (330–980 ft). Penstock diameters are between 1 and 10 m (3.3 and 32.8 ft). The speeds of different turbine units range from 70 to 1000 rpm . A wicket gate around
92-509: A reservoir is filled by the turbine (acting as a pump) driven by the generator acting as a large electrical motor during periods of low power demand, and then reversed and used to generate power during peak demand. These pump storage reservoirs act as large energy storage sources to store "excess" electrical energy in the form of water in elevated reservoirs. This is one of a few methods that allow temporary excess electrical capacity to be stored for later utilization. Volute (pump) A volute
115-436: A wide range of heads and flows. This versatility, along with their high efficiency, has made them the most widely used turbine in the world. Francis type units cover a head range from 40 to 600 m (130 to 2,000 ft), and their connected generator output power varies from just a few kilowatts up to 1000 MW. Large Francis turbines are individually designed for each site to operate with the given water flow and water head at
138-411: Is a curved funnel that increases in area as it approaches the discharge port. The volute of a centrifugal pump is the casing that receives the fluid being pumped by the impeller , maintaining the velocity of the fluid through to the diffuser. As liquid exits the impeller it has high kinetic energy and the volute directs this flow through to the discharge. As the fluid travels along the volute it
161-404: Is a type of reaction turbine, a category of turbine in which the working fluid comes to the turbine under immense pressure and the energy is extracted by the turbine blades from the working fluid. A part of the energy is given up by the fluid because of pressure changes occurring on the blades of the turbine, quantified by the expression of degree of reaction , while the remaining part of the energy
184-475: Is an inward-flow reaction turbine that combines radial and axial flow concepts. Francis turbines are the most common water turbine in use today, and can achieve over 95% efficiency. The process of arriving at the modern Francis runner design took from 1848 to approximately 1920. It became known as the Francis turbine around 1920, being named after British-American engineer James B. Francis who in 1848 created
207-472: Is equal to that at the inlet to the draft tube. Using the Euler turbine equation, E / m = e = V w1 U 1 , where e is the energy transfer to the rotor per unit mass of the fluid. From the inlet velocity triangle, and Therefore The loss of kinetic energy per unit mass at the outlet is V f2 /2 . Therefore, neglecting friction, the blade efficiency becomes i.e. Degree of reaction can be defined as
230-445: Is extracted by the volute casing of the turbine. At the exit, water acts on the spinning cup-shaped runner features, leaving at low velocity and low swirl with very little kinetic or potential energy left. The turbine's exit tube is shaped to help decelerate the water flow and recover the pressure. Usually the flow velocity (velocity perpendicular to the tangential direction) remains constant throughout, i.e. V f1 = V f2 and
253-407: Is joined by more and more fluid exiting the impeller but, as the cross sectional area of the volute increases, the velocity is maintained if the pump is running close to the design point. If the pump has a low flow rate then the velocity will decrease across the volute leading to a pressure rise causing a cross thrust across the impeller that we see as vibration. If the pump flow is higher than design
SECTION 10
#1732854633907276-455: Is necessary, as these are major parameters affecting power production. Draft tube : The draft tube is a conduit that connects the runner exit to the tail race where the water is discharged from the turbine. Its primary function is to reduce the velocity of discharged water to minimize the loss of kinetic energy at the outlet. This permits the turbine to be set above the tail water without appreciable drop of available head. The Francis turbine
299-406: The design of high-efficiency turbines to precisely match a site's water flow and pressure ( water head ). A Francis turbine consists of the following main parts: Spiral casing : The spiral casing around the runner of the turbine is known as the volute casing or scroll case. Throughout its length, it has numerous openings at regular intervals to allow the working fluid to impinge on the blades of
322-444: The diffuser by reducing liquid velocity while increasing pressure. The name "volute" is inspired by the resemblance of this kind of casing to the scroll-like part near the top of an ionic order column in classical architecture , called a volute . In a split volute or double volute pump, the path along the volute is partitioned, providing two distinct discharge paths. The streams start out 180 degrees from each other, and merge by
345-436: The guide and stay vanes is to convert the pressure energy of the fluid into kinetic energy. It also serves to direct the flow at design angles to the runner blades. Runner blades : Runner blades are the heart of any turbine. These are the centers where the fluid strikes and the tangential force of the impact produces torque causing the shaft of the turbine to rotate. Close attention to design of blade angles at inlet and outlet
368-456: The highest possible efficiency, typically over 90% (to 99% ). In contrast to the Pelton turbine , the Francis turbine operates at its best completely filled with water at all times. The turbine and the outlet channel may be placed lower than the lake or sea level outside, reducing the tendency for cavitation . In addition to electrical production , they may also be used for pumped storage , where
391-607: The outside of the turbine's rotating runner controls the rate of water flow through the turbine for different power production rates. Francis turbines are usually mounted with a vertical shaft, to isolate water from the generator. This also facilitates installation and maintenance. Water wheels of different types have been used for more than 1,000 years to power mills of all types, but they were relatively inefficient. Nineteenth-century efficiency improvements of water turbines allowed them to replace nearly all water wheel applications and compete with steam engines wherever water power
414-433: The ratio of pressure energy change in the blades to total energy change of the fluid. This means that it is a ratio indicating the fraction of total change in fluid pressure energy occurring in the blades of the turbine. The rest of the changes occur in the stator blades of the turbines and the volute casing as it has a varying cross-sectional area. For example, if the degree of reaction is given as 50%, that means that half of
437-400: The runner. These openings convert the pressure energy of the fluid into kinetic energy just before the fluid impinges on the blades. This maintains a constant velocity despite the fact that numerous openings have been provided for the fluid to enter the blades, as the cross-sectional area of this casing decreases uniformly along the circumference. Guide and stay vanes : The primary function of
460-602: The same principles. S. B. Howd obtained a US patent in 1838 for a similar design. In 1848 James B. Francis , while working as head engineer of the Locks and Canals company in the water wheel-powered textile factory city of Lowell, Massachusetts , improved on these designs to create more efficient turbines. He applied scientific principles and testing methods to produce a very efficient turbine design. More importantly, his mathematical and graphical calculation methods improved turbine design and engineering. His analytical methods allowed
483-876: The total energy change of the fluid is taking place in the rotor blades and the other half is occurring in the stator blades. If the degree of reaction is zero it means that the energy changes due to the rotor blades is zero, leading to a different turbine design called the Pelton Turbine . The second equality above holds, since discharge is radial in a Francis turbine. Now, putting in the value of 'e' from above and using V 1 2 − V f 2 2 = V f 1 2 cot α 2 {\displaystyle V_{1}^{2}-V_{f2}^{2}=V_{f1}^{2}\cot \alpha _{2}} (as V f 2 = V f 1 {\displaystyle V_{f2}=V_{f1}} ) Francis turbines may be designed for
SECTION 20
#1732854633907506-401: The velocity will increase across the volute and the pressure will decrease according to the first law of thermodynamics. This will cause a side thrust in the opposite direction to that caused by low flow but the result is the same – vibration with resultant short bearing and seal life. The volute does not convert kinetic energy into pressure – that is done at
529-516: Was available. After electric generators were developed in the late 1800s, turbines were a natural source of generator power where potential hydropower sources existed. In 1826 the French engineer Benoit Fourneyron developed a high-efficiency (80%) outward-flow water turbine. Water was directed tangentially through the turbine runner, causing it to spin. Another French engineer, Jean-Victor Poncelet , designed an inward-flow turbine in about 1820 that used
#906093