Misplaced Pages

Unistar

Article snapshot taken from Wikipedia with creative commons attribution-sharealike license. Give it a read and then ask your questions in the chat. We can research this topic together.

UniStar Nuclear Energy is a wholly owned subsidiary of EDF ( Électricité de France ), formed in 2007 to develop new nuclear energy facilities in the United States.

#952047

64-664: Unistar has one project under development, Calvert Cliffs Unit 3 in Maryland - the reference plant for the Areva , U.S. EPR design. The Nuclear Regulatory Commission is currently reviewing UniStar's Combined License (COL) application for this facility. UniStar is also assisting PPL Corporation with the development of their Bell Bend Unit 1 project, which is also a U.S. EPR design. Created in 2005 by Constellation Energy and Areva , UniStar Nuclear became UniStar Nuclear Energy in August 2007 -

128-449: A pultruded fiber-reinforced plastic (FRP) structure, FRP cladding , a mechanical unit for air draft , and a drift eliminator. With respect to the heat transfer mechanism employed, the main types are: In a wet cooling tower (or open circuit cooling tower), the warm water can be cooled to a temperature lower than the ambient air dry-bulb temperature, if the air is relatively dry (see dew point and psychrometrics ). As ambient air

192-533: A Delaware limited liability company , was jointly owned by Constellation Energy (CEG) and Électricité de France (EDF), the French builder and supplier of nuclear power plants. The proposed unit was to produce approximately twice the energy of each individual existing unit. On July 13, 2007, UniStar Nuclear Energy filed a partial application to the Nuclear Regulatory Commission to review its plans to build

256-456: A chiller coefficient of performance (COP) of 4.0. This COP is equivalent to an energy efficiency ratio (EER) of 14. Cooling towers are also used in HVAC systems that have multiple water source heat pumps that share a common piping water loop . In this type of system, the water circulating inside the water loop removes heat from the condenser of the heat pumps whenever the heat pumps are working in

320-482: A chimney stack much shortened vertically (20 to 40 ft. high) and very much enlarged laterally. At the top is a set of distributing troughs, to which the water from the condenser must be pumped; from these it trickles down over "mats" made of wooden slats or woven wire screens, which fill the space within the tower". A hyperboloid cooling tower was patented by the Dutch engineers Frederik van Iterson and Gerard Kuypers in

384-433: A cooling heat-sink for the plant. Unit 1 went into commercial service in 1975 and Unit 2 in 1977. The total cost of the two units was approximately US$ 766 million, about $ 3.699 billion in 2024. Unit 1 had its two steam generators replaced in 2002 and its reactor vessel closure head replaced in 2006, while unit 2 had its two steam generators replaced in 2003, and its vessel closure head replaced in 2007. The water around

448-513: A decade, according to an analysis of U.S. Census data for msnbc.com. The 2010 U.S. population within 50 miles (80 km) was 2,890,702, a decrease of 2.0 percent since 2000. Cities within 50 miles include Washington, D.C., (45 miles to city center). In 2001, when the Dominion Cove Point LNG plant was scheduled to reopen, many local residents were concerned about the proximity to this nuclear power plant (3 miles). Residents thought that

512-434: A deep pan with holes or nozzles in its bottom is located near the top of a crossflow tower. Gravity distributes the water through the nozzles uniformly across the fill material. Cross Flow V/s Counter Flow Advantages of the crossflow design: Disadvantages of the crossflow design: In a counterflow design, the air flow is directly opposite to the water flow (see diagram at left). Air flow first enters an open area beneath

576-512: A fee would doom the project, “or the economics of any nuclear project, for that matter”. In November 2010 a deal to transfer Constellation Energy Group's stake in a nuclear development company to its French partner, EDF Group, closed, according to the U.S. Securities and Exchange Commission . A month prior, Constellation agreed to sell its 50 percent stake in UniStar Nuclear Energy to EDF for US$ 140 million, giving EDF sole ownership of

640-563: A joint venture by Constellation Energy and EDF . In 2010, EDF acquired 100 percent of UniStar Nuclear Energy. In 2008, UniStar also submitted a Combined Operating License Application for a new nuclear unit in Oswego NY , to be named Nine Mile Point Unit 3 . UniStar failed to acquire the land rights from Constellation Energy (and other parties) and subsequently terminated the NMP3 project in 2013. In February 2014, after significant staff reductions

704-514: A method for steam recapture. The steam is charged using an ion beam, and then captured in a wire mesh of opposite charge. The water's purity exceeded EPA potability standards. An HVAC (heating, ventilating, and air conditioning) cooling tower is used to dispose of ("reject") unwanted heat from a chiller . Liquid-cooled chillers are normally more energy efficient than air-cooled chillers due to heat rejection to tower water at or near wet-bulb temperatures . Air-cooled chillers must reject heat at

SECTION 10

#1732868668953

768-552: A new nuclear power plant, Calvert Cliffs Nuclear Power Plant 3 (CCNPP 3) based on the AREVA US Evolutionary Power Reactor (US-EPR), Generation III+, four loop pressurized water reactor. The third reactor was intended to address a need for more baseload power generation in the Mid-Atlantic region. The unit proposed to be located south of the existing units 1 and 2, set back from the shoreline. Although only

832-427: A plume exposure pathway zone with a radius of 10 miles (16 km), concerned primarily with exposure to, and inhalation of, airborne radioactive contamination , and an ingestion pathway zone of about 50 miles (80 km), concerned primarily with ingestion of food and liquid contaminated by radioactivity. The 2010 US population within 10 miles (16 km) of Calvert Cliffs was 48,798, an increase of 86.4 percent in

896-489: A single unit, its power plant footprint was almost twice the size of the existing units together. It was to have a closed-loop cooling system using a single hybrid mechanical draft cooling tower, incorporating plume abatement for no visible water vapor plume from the tower. Units 1 and 2 use an open-cycle heat dissipation system without cooling towers. The cooling tower of the Unit 3 reactor was to release two thirds of its waste heat to

960-416: A small amount of the water to be lost as windage or drift (W) and some of the water (E) to evaporate . The heat required to evaporate the water is derived from the water itself, which cools the water back to the original basin water temperature and the water is then ready to recirculate. The evaporated water leaves its dissolved salts behind in the bulk of the water which has not been evaporated, thus raising

1024-534: A typical 700 MW th coal-fired power plant with a cooling tower amounts to about 71,600 cubic metres an hour (315,000 US gallons per minute) and the circulating water requires a supply water make-up rate of perhaps 5 percent (i.e., 3,600 cubic metres an hour, equivalent to one cubic metre every second). If that same plant had no cooling tower and used once-through cooling water, it would require about 100,000 cubic metres an hour A large cooling water intake typically kills millions of fish and larvae annually, as

1088-518: Is a stub . You can help Misplaced Pages by expanding it . This article about a United States company or corporation involved in the energy industry is a stub . You can help Misplaced Pages by expanding it . Calvert Cliffs Nuclear Power Plant#Proposal to add a third reactor The Calvert Cliffs Nuclear Power Plant ( CCNPP ) is a nuclear power plant located on the western shore of the Chesapeake Bay near Lusby , Calvert County , Maryland, in

1152-457: Is a design in which the airflow is directed perpendicular to the water flow (see diagram at left). Airflow enters one or more vertical faces of the cooling tower to meet the fill material. Water flows (perpendicular to the air) through the fill by gravity. The air continues through the fill and thus past the water flow into an open plenum volume. Lastly, a fan forces the air out into the atmosphere. A distribution or hot water basin consisting of

1216-469: Is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers , rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators . Common applications include cooling

1280-417: Is a relatively more important issue for package type cooling towers. Facilities such as power plants, steel processing plants, petroleum refineries, or petrochemical plants usually install field-erected type cooling towers due to their greater capacity for heat rejection. Field-erected towers are usually much larger in size compared to the package type cooling towers. A typical field-erected cooling tower has

1344-576: Is being considered in Case Number 9127. Opponents and supporters of the proposed third reactor at Calvert Cliffs were involved in a series of public hearings before officials of the US Nuclear Regulatory Commission . In March 2009, Bill Peil of southern Calvert County asked the NRC to deny an emissions permit for the reactor due to health and safety concerns he asserted that the plant posed to

SECTION 20

#1732868668953

1408-574: Is defined as the removal of 12,000 British thermal units per hour (3.5 kW). The equivalent ton on the cooling tower side actually rejects about 15,000 British thermal units per hour (4.4 kW) due to the additional waste-heat–equivalent of the energy needed to drive the chiller's compressor. This equivalent ton is defined as the heat rejection in cooling 3 US gallons per minute (11 litres per minute) or 1,500 pounds per hour (680 kg/h) of water by 10 °F (5.6 °C), which amounts to 15,000 British thermal units per hour (4.4 kW), assuming

1472-400: Is drawn past a flow of water, a small portion of the water evaporates, and the energy required to evaporate that portion of the water is taken from the remaining mass of water, thus reducing its temperature. Approximately 2,300 kilojoules per kilogram (970 BTU/lb) of heat energy is absorbed for the evaporated water. Evaporation results in saturated air conditions, lowering the temperature of

1536-452: Is not an issue with marine engines , it forms a significant limitation for many land-based systems. By the turn of the 20th century, several evaporative methods of recycling cooling water were in use in areas lacking an established water supply, as well as in urban locations where municipal water mains may not be of sufficient supply, reliable in times of high demand, or otherwise adequate to meet cooling needs. In areas with available land,

1600-399: Is returned to the bay no more than 12 °F (6.7 °C) warmer than the bay water. Unlike many other nuclear power plants, Calvert Cliffs did not have to utilize water cooling towers to return the hot water to its original temperature. As the water comes out very quickly and creates a sort of artificial rip current , it can be a dangerous place to fish. CCNPP 3 will only need about 10% of

1664-630: Is supplied by other means, usually from separate boilers . Industrial cooling towers can be used to remove heat from various sources such as machinery or heated process material. The primary use of large, industrial cooling towers is to remove the heat absorbed in the circulating cooling water systems used in power plants , petroleum refineries , petrochemical plants, natural gas processing plants, food processing plants, semi-conductor plants, and for other industrial facilities such as in condensers of distillation columns, for cooling liquid in crystallization, etc. The circulation rate of cooling water in

1728-745: Is the 210 metres (690 ft) tall cooling tower of the Pingshan II Power Station in Huaibei , Anhui Province, China. These types of cooling towers are factory preassembled, and can be simply transported on trucks, as they are compact machines. The capacity of package type towers is limited and, for that reason, they are usually preferred by facilities with low heat rejection requirements such as food processing plants, textile plants, some chemical processing plants, or buildings like hospitals, hotels, malls, automotive factories, etc. Due to their frequent use in or near residential areas, sound level control

1792-523: Is what necessitates the cooling tower. Although these large towers are very prominent, the vast majority of cooling towers are much smaller, including many units installed on or near buildings to discharge heat from air conditioning . Cooling towers are also often thought to emit smoke or harmful fumes by the general public and environmental activists, when in reality the emissions from those towers mostly do not contribute to carbon footprint , consisting solely of water vapor . Cooling towers originated in

1856-542: The Federal Energy Regulatory Commission did not consider the risks could be caused by an attack or an explosion before opening the plant. The NRC's estimate of the risk each year of an earthquake intense enough to cause core damage to the reactor at Calvert Cliffs was 1 in 100,000 for Reactor 1 and 1 in 83,333 for Reactor 2, according to an NRC study published in August 2010. In the 1960s scientists at Johns Hopkins University became concerned that

1920-647: The Mid-Atlantic United States . It is the only nuclear power plant in the state of Maryland. The plant is owned and operated by Constellation Energy and has two 2737 megawatt thermal (MWth) Combustion Engineering Generation II two-loop pressurized water reactors . Each generating plant (CCNPP 1&2) produces approximately 850 megawatt electrical (MWe) net or 900 MWe gross. Each plant's electrical load consumes approximately 50 MWe. These are saturated steam plants (non-superheated) and are approximately 33% efficient (ratio of 900 MWe gross/2700 MWth core). Only

1984-511: The 19th century through the development of condensers for use with the steam engine . Condensers use relatively cool water, via various means, to condense the steam coming out of the cylinders or turbines. This reduces the back pressure , which in turn reduces the steam consumption, and thus the fuel consumption, while at the same time increasing power and recycling boiler water. However, the condensers require an ample supply of cooling water, without which they are impractical. While water usage

Unistar - Misplaced Pages Continue

2048-491: The M-Cycle HMX for air conditioning, through engineering design this cycle could be applied as a heat- and moisture-recovery device for combustion devices, cooling towers, condensers, and other processes involving humid gas streams. The consumption of cooling water by inland processing and power plants is estimated to reduce power availability for the majority of thermal power plants by 2040–2069. In 2021, researchers presented

2112-633: The NRC extended the license of the plant for 20 additional years, making Calvert Cliffs the first nuclear plant in the United States to receive such an extension. President George W. Bush visited the plant in June 2005, the first time a president had visited a nuclear power plant in nearly two decades. UniStar Nuclear Energy announced plans to build a unit of the Evolutionary Power Reactor ( US-EPR variant) at Calvert Cliffs. UniStar Nuclear Energy,

2176-700: The Netherlands on August 16, 1916. The first hyperboloid reinforced concrete cooling towers were built by the Dutch State Mine (DSM) Emma in 1918 in Heerlen . The first ones in the United Kingdom were built in 1924 at Lister Drive power station in Liverpool , England. On both locations they were built to cool water used at a coal-fired electrical power station. According to a Gas Technology Institute (GTI) report ,

2240-647: The UK patent (108,863) for Improved Construction of Cooling Towers of Reinforced Concrete . The patent was filed on 9 August 1917, and published on 11 April 1918. In 1918, DSM built the first hyperboloid natural-draft cooling tower at the Staatsmijn Emma , to his design. Hyperboloid (sometimes incorrectly known as hyperbolic ) cooling towers have become the design standard for all natural-draft cooling towers because of their structural strength and minimum usage of material. The hyperboloid shape also aids in accelerating

2304-570: The accumulation of dissolved minerals in the recirculating cooling water. Discharge of draw-off (or blowdown) is used principally to control the buildup of these minerals. The chemistry of the make-up water, including the amount of dissolved minerals, can vary widely. Make-up waters low in dissolved minerals such as those from surface water supplies (lakes, rivers etc.) tend to be aggressive to metals (corrosive). Make-up waters from ground water supplies (such as wells ) are usually higher in minerals, and tend to be scaling (deposit minerals). Increasing

2368-420: The amount of minerals present in the water by cycling can make water less aggressive to piping; however, excessive levels of minerals can cause scaling problems. As the cycles of concentration increase, the water may not be able to hold the minerals in solution . When the solubility of these minerals have been exceeded they can precipitate out as mineral solids and cause fouling and heat exchange problems in

2432-557: The atmosphere. The proposed EPR design was a saturated steam plant with one high-pressure turbine in tandem with three low-pressure turbines and a main generator design similar to Unit 1 and 2. Alstom was to supply the main steam turbine and main generator. On November 13, 2007, UniStar Nuclear Energy filed an application for a certificate of public convenience and necessity with the Maryland Public Service Commission for authority to construct CCNPP 3. This application

2496-515: The bay cooling water volume needed for Unit 1 and 2 combined. The increase in fish and shellfish impingement and entrainment will be less than 3.5% over Unit 1 and 2 existing conditions. In February 2009, Calvert Cliffs set a world record for pressurized water reactors (PWRs) by operating 692 days non-stop. In addition, Unit 2's capacity factor in 2008 was a world-record high of 101.37 percent. The Nuclear Regulatory Commission (NRC) defines two emergency planning zones around nuclear power plants:

2560-860: The circulating water used in oil refineries , petrochemical and other chemical plants , thermal power stations , nuclear power stations and HVAC systems for cooling buildings. The classification is based on the type of air induction into the tower: the main types of cooling towers are natural draft and induced draft cooling towers. Cooling towers vary in size from small roof-top units to very large hyperboloid structures that can be up to 200 metres (660 ft) tall and 100 metres (330 ft) in diameter, or rectangular structures that can be over 40 metres (130 ft) tall and 80 metres (260 ft) long. Hyperboloid cooling towers are often associated with nuclear power plants , although they are also used in many coal-fired plants and to some extent in some large chemical and other industrial plants. The steam turbine

2624-457: The community. UniStar Nuclear Energy President and CEO George Vanderheyden urged the NRC to approve the air permit application. In October 2010, Constellation Energy said that it had reached an impasse in negotiations for a federal loan guarantee to build the proposed third reactor. The government sought a fee of $ 880 million on a guarantee of about $ 7.6 billion, to compensate taxpayers for the risk of default. Constellation Energy replied that such

Unistar - Misplaced Pages Continue

2688-477: The cooling mode, then the externally mounted cooling tower is used to remove heat from the water loop and reject it to the atmosphere . By contrast, when the heat pumps are working in heating mode, the condensers draw heat out of the loop water and reject it into the space to be heated. When the water loop is being used primarily to supply heat to the building, the cooling tower is normally shut down (and may be drained or winterized to prevent freeze damage), and heat

2752-529: The cooling tower or the heat exchangers . The temperatures of the recirculating water, piping and heat exchange surfaces determine if and where minerals will precipitate from the recirculating water. Often a professional water treatment consultant will evaluate the make-up water and the operating conditions of the cooling tower and recommend an appropriate range for the cycles of concentration. The use of water treatment chemicals, pretreatment such as water softening , pH adjustment, and other techniques can affect

2816-532: The deployment of a European reactor in the US. Unit 2 at the Calvert Cliffs nuclear power plant was shut down on September 5, 2013, after a malfunction during testing. It was re-opened September 10, 2013, after the required maintenance was performed. The Calvert Cliffs Nuclear Power Plant consist of two operational reactors, one additional was proposed in 2007 and withdrawn. Cooling tower A cooling tower

2880-647: The discharge of heated cooling water from the plant would be detrimental to a crucial element of the Chesapeake Bay ecosystem, the bay's famed blue crabs . Litigation pursuant to the 1970 National Environmental Policy Act led to a 1971 decision by the District of Columbia Court of Appeals requiring the Atomic Energy Commission (succeeded by the NRC in 1974) to consider the environmental impact of building and maintaining such an atomic energy plant. In 2000,

2944-466: The entire system is then: Since the evaporated water (E) has no salts, a chloride balance around the system is: and, therefore: From a simplified heat balance around the cooling tower: Windage (or drift) losses (W) is the amount of total tower water flow that is entrained in the flow of air to the atmosphere. From large-scale industrial cooling towers, in the absence of manufacturer's data, it may be assumed to be: Cycle of concentration represents

3008-402: The exhaust of the single high-pressure main turbine is slightly superheated by a two-stage reheater before delivering the superheated steam in parallel to the three low-pressure turbines. Unit 1 uses a General Electric–designed main turbine and generator, while Unit 2 uses a Westinghouse–designed main turbine and generator. The heat produced by the reactor is returned to the bay, which operates as

3072-443: The fill media, and is then drawn up vertically. The water is sprayed through pressurized nozzles near the top of the tower, and then flows downward through the fill, opposite to the air flow. Advantages of the counterflow design: Disadvantages of the counterflow design: Common aspects of both designs: Both crossflow and counterflow designs can be used in natural draft and in mechanical draft cooling towers. Quantitatively,

3136-436: The heat into the atmosphere instead, so that wind and air diffusion spreads the heat over a much larger area than hot water can distribute heat in a body of water. Evaporative cooling water cannot be used for subsequent purposes (other than rain somewhere), whereas surface-only cooling water can be re-used. Some coal-fired and nuclear power plants located in coastal areas do make use of once-through ocean water. But even there,

3200-440: The higher dry-bulb temperature , and thus have a lower average reverse– Carnot-cycle effectiveness. In hot climates, large office buildings, hospitals, and schools typically use cooling towers in their air conditioning systems. Generally, industrial cooling towers are much larger than HVAC towers. HVAC use of a cooling tower pairs the cooling tower with a liquid-cooled chiller or liquid-cooled condenser. A ton of air-conditioning

3264-402: The hot process streams which need to be cooled or condensed, and the absorbed heat warms the circulating water (C). The warm water returns to the top of the cooling tower and trickles downward over the fill material inside the tower. As it trickles down, it contacts ambient air rising up through the tower either by natural draft or by forced draft using large fans in the tower. That contact causes

SECTION 50

#1732868668953

3328-402: The indirect–dew-point evaporative-cooling Maisotsenko Cycle (M-Cycle) is a theoretically sound method of reducing a working fluid to the ambient fluid’s dew point, which is lower than the ambient fluid’s wet-bulb temperature. The M-cycle utilizes the psychrometric energy (or the potential energy) available from the latent heat of water evaporating into the air. While its current manifestation is as

3392-562: The joint venture and its plans to develop a third unit at Calvert Cliffs in Southern Maryland. The deal called for EDF to transfer 3.5 million shares it owns, valued around US$ 110 million, to Constellation and give up its seat on the Constellation board. EDF designee Samuel Minzberg resigned. In April 2011 the NRC stated that UniStar is not eligible to build a third reactor, as it is not a US owned company since Constellation pulled out of

3456-419: The material balance around a wet, evaporative cooling tower system is governed by the operational variables of make-up volumetric flow rate , evaporation and windage losses, draw-off rate, and the concentration cycles. In the adjacent diagram, water pumped from the tower basin is the cooling water routed through the process coolers and condensers in an industrial facility. The cool water absorbs heat from

3520-414: The offshore discharge water outlet requires very careful design to avoid environmental problems. Petroleum refineries may also have very large cooling tower systems. A typical large refinery processing 40,000 metric tonnes of crude oil per day (300,000 barrels (48,000 m ) per day) circulates about 80,000 cubic metres of water per hour through its cooling tower system. The world's tallest cooling tower

3584-621: The organisms are impinged on the intake screens . A large amount of water would have to be continuously returned to the ocean, lake or river from which it was obtained and continuously re-supplied to the plant. Furthermore, discharging large amounts of hot water may raise the temperature of the receiving river or lake to an unacceptable level for the local ecosystem. Elevated water temperatures can kill fish and other aquatic organisms (see thermal pollution ), or can also cause an increase in undesirable organisms such as invasive species of zebra mussels or algae . A cooling tower serves to dissipate

3648-489: The partnership in 2010. The NRC would continue to process the application, but a license would not be issued until the ownership requirements were met. The reactor was estimated to cost $ 9.6 billion. Constellation Energy merged into Exelon in 2012. In 2015 Areva, struggling with internal restructuring of its corporation, withdrew from the certification process for the US EPR reactor design, effectively putting on hold plans for

3712-436: The plant (see lower-right-center of photograph) is a very popular place for anglers . Unit 1 & 2 each takes in bay water (from the fenced-in area) to cool its steam driven turbine condensers plus other bay-water–cooled primary and secondary system heat exchangers. The bay water is pumped out at a nominal flow rate of 1.2 million gallons per minute (75,000 L/s) per unit (Unit 1 and 2) for each steam turbine condenser. The water

3776-639: The prior year, UniStar vacated its Baltimore MD office and moved remaining staff to the EDF North America Headquarters in Chevy Chase MD . UniStar continues to pursue the a COL for the Calvert Cliffs Unit 3 project, however continued delays by AREVA to obtain the U.S. NRC approval of the U.S. EPR design (i.e. Design Certification) have delayed the project. This article about nuclear power and nuclear reactors for power generation

3840-432: The salt concentration in the circulating cooling water. To prevent the salt concentration of the water from becoming too high, a portion of the water is drawn off or blown down (D) for disposal. Fresh water make-up (M) is supplied to the tower basin to compensate for the loss of evaporated water, the windage loss water and the draw-off water. Using these flow rates and concentration dimensional units: A water balance around

3904-422: The systems took the form of cooling ponds ; in areas with limited land, such as in cities, they took the form of cooling towers. These early towers were positioned either on the rooftops of buildings or as free-standing structures, supplied with air by fans or relying on natural airflow. An American engineering textbook from 1911 described one design as "a circular or rectangular shell of light plate—in effect,

SECTION 60

#1732868668953

3968-582: The upward convective air flow, improving cooling efficiency. These designs are popularly associated with nuclear power plants . However, this association is misleading, as the same kind of cooling towers are often used at large coal-fired power plants and some geothermal plants as well. The steam turbine is what necessitates the cooling tower. Conversely, not all nuclear power plants have cooling towers, and some instead cool their working fluid with lake, river or ocean water. Typically lower initial and long-term cost, mostly due to pump requirements. Crossflow

4032-407: The water flow causing splashing. Film fill is composed of thin sheets of material (usually PVC ) upon which the water flows. Both methods create increased surface area and time of contact between the fluid (water) and the gas (air), to improve heat transfer. With respect to drawing air through the tower, there are three types of cooling towers: On 16 August 1916, Frederik van Iterson took out

4096-422: The water processed by the tower to a value close to wet-bulb temperature , which is lower than the ambient dry-bulb temperature , the difference determined by the initial humidity of the ambient air. To achieve better performance (more cooling), a medium called fill is used to increase the surface area and the time of contact between the air and water flows. Splash fill consists of material placed to interrupt

#952047